EUVIMEDAtrasti EUVIMED
Crossref

Simulation of Space Charge Effects in Fourier Transform Quadrupole Ion Traps (FT-QITs)

Walter Wißdorf iD, Marco Thinius, Thorsten Benter iD

Journal of the American Society for Mass Spectrometry · 2024-12-04 · 35 (12) · 2969-2983

DOI: 10.1021/jasms.4c00296 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2024-11-06. Written by Walter Wißdorf and 2 co-authors. Institution: Department of Physical and Theoretical Chemistry, University of Wuppertal, Gaussstraße 20, 42119 Wuppertal, Germany. Cited 3 times so far (Crossref); 50 references.

SantraukaBibliografiniai duomenysCiteRelated studies

Abstract (original language)

We present ion dynamics simulations regarding the effect of space charge on the performance of Fourier transform quadrupole ion traps (FT-QITs) with special attention to signal stability, mass resolving power, and sensitivity. Ion trajectory simulations within an idealized QIT geometry are performed by applying a dedicated application (QITSim) using an in-house developed open simulation framework (IDSimF). Image current detection transients are generated by the application and are subsequently transformed into frequency spectra of ion secular motion. Such frequency spectra are the basis for the calculation of mass spectra in FT-QIT instruments. The simulation results are used to assess the extent of space charge induced effects regarding the analytical performance of FT-QIT systems. The simulation results for two Cl+ and seven Xe+ isotope ions exhibit diverse space charge induced phenomena. Most prominently, complete isotope signal fusion, quantitative individual signal suppression, and severe signal distortions are observed even at low absolute numbers of trapped ions. Furthermore, significant shifts of the secular oscillation frequencies occur, even when the signal shape appears to be mostly unaffected and when the frequency separation for trapped ions with different masses is large. This significantly limits the applicability of FT-QIT systems for high resolution mass spectrometry. An increase of the RF amplitude of the trapping field as well as increasing the extent of ion excitation partly mitigate these adverse space charge effects; nevertheless, the usable operational range of the simulated FT-QIT system for analytical applications remains rather narrow.

Authors and institutions

  • Department of Physical and Theoretical Chemistry, University of Wuppertal, Gaussstraße 20, 42119 Wuppertal, Germany.

ORCID profiles: Walter Wißdorf, Thorsten Benter

Cite

APA

Wißdorf, W., Thinius, M., & Benter, T. (2024). Simulation of Space Charge Effects in Fourier Transform Quadrupole Ion Traps (FT-QITs). Journal of the American Society for Mass Spectrometry, 35(12), 2969-2983. https://doi.org/10.1021/jasms.4c00296

Vancouver

Wißdorf W, Thinius M, Benter T. Simulation of Space Charge Effects in Fourier Transform Quadrupole Ion Traps (FT-QITs). Journal of the American Society for Mass Spectrometry. 2024;35(12):2969-2983. doi:10.1021/jasms.4c00296

BibTeX
@article{Widorf2024,
  author = {Wißdorf, Walter and Thinius, Marco and Benter, Thorsten},
  title = {Simulation of Space Charge Effects in Fourier Transform Quadrupole Ion Traps (FT-QITs)},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  volume = {35},
  number = {12},
  pages = {2969--2983},
  doi = {10.1021/jasms.4c00296}
}