EUVIMEDOpdag EUVIMED
Crossref

MALDI-2-Enabled Oversampling for the Mass Spectrometry Imaging of Metabolites at Single-Cell Resolution

Jayden C McKinnon, Rachelle Balez, Reuben S E Young, Mikayla L Brown iD, Jeremy S Lum, Liam Robinson, Mikhail E Belov iD, Lezanne Ooi iD, Sara Tortorella iD, Todd W Mitchell, Shane R Ellis iD

Journal of the American Society for Mass Spectrometry · 2024-11-06 · 35 (11) · 2729-2742

DOI: 10.1021/jasms.4c00241 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2024-08-13. Written by Jayden C McKinnon and 10 co-authors. Institution: Molecular Horizons and School of Chemistry and Molecular Bioscience, University of Wollongong, Northfields Ave, Wollongong, NSW 2522, Australia. Major MEDLINE topics: Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Single-Cell Analysis. Cited 43 times so far (Crossref); 58 references. Funded by: Motor Neurone Disease Research Institute of Australia, FightMND, National Health and Medical Research Council.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) can provide valuable insights into the metabolome of complex biological systems such as organ tissues and cells. However, obtaining metabolite data at single-cell spatial resolutions presents a few technological challenges. Generally, spatial resolution is defined by the increment the sample stage moves between laser ablation spots. Stage movements less than the diameter of the focused laser beam (i.e., oversampling) can improve spatial resolution; however, such oversampling conditions result in a reduction in sensitivity. To overcome this, we combine an oversampling approach with laser postionization (MALDI-2), which allows for both higher spatial resolution and improved analyte ionization efficiencies. This approach provides significant enhancements to sensitivity for various metabolite classes (e.g., amino acids, purines, carbohydrates etc.), with mass spectral intensities from 6 to 8 μm pixel sizes (from a laser spot size of ∼13 μm) being commensurate with or higher than those obtained by conventional MALDI at 20 μm pixel sizes for many different metabolites. This technique has been used to map the distribution of metabolites throughout mouse spinal cord tissue to observe how metabolite localizations change throughout specific anatomical regions, such as those distributed to the somatosensory area of the dorsal horn, white matter, gray matter, and ventral horn. Furthermore, this method is utilized for single-cell metabolomics of human iPSC-derived astrocytes at 10 μm pixel sizes whereby many different metabolites, including nucleotides, were detected from individual cells while providing insight into cellular localizations.

Subjects

MeSH terms (MEDLINE)

Spectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationSingle-Cell AnalysisAnimalsMiceSpinal CordMetabolomeMetabolomicsMice, Inbred C57BL

Authors and institutions

  • Molecular Horizons and School of Chemistry and Molecular Bioscience, University of Wollongong, Northfields Ave, Wollongong, NSW 2522, Australia.
  • Molecular Horizons, School of Medical, Indigenous and Health Science, University of Wollongong, Northfields Ave, Wollongong, NSW 2522, Australia.
  • Spectroglyph LLC, Kennewick, Washington 99338, United States.
  • Molecular Horizon srl, Via Montelino 30, Bettona, PG 06084, Italy.

ORCID profiles: Mikayla L Brown, Mikhail E Belov, Lezanne Ooi, Sara Tortorella, Shane R Ellis

Funding

  • Motor Neurone Disease Research Institute of Australia
  • FightMND
  • National Health and Medical Research Council
  • Australian Research Council
  • Australian Government

Cite

APA

McKinnon, J. C., Balez, R., Young, R. S. E., Brown, M. L., Lum, J. S., Robinson, L., Belov, M. E., Ooi, L., Tortorella, S., Mitchell, T. W., & Ellis, S. R. (2024). MALDI-2-Enabled Oversampling for the Mass Spectrometry Imaging of Metabolites at Single-Cell Resolution. Journal of the American Society for Mass Spectrometry, 35(11), 2729-2742. https://doi.org/10.1021/jasms.4c00241

Vancouver

McKinnon JC, Balez R, Young RSE, Brown ML, Lum JS, Robinson L, et al. MALDI-2-Enabled Oversampling for the Mass Spectrometry Imaging of Metabolites at Single-Cell Resolution. Journal of the American Society for Mass Spectrometry. 2024;35(11):2729-2742. doi:10.1021/jasms.4c00241

BibTeX
@article{McKinnon2024,
  author = {McKinnon, Jayden C and Balez, Rachelle and Young, Reuben S E and Brown, Mikayla L and Lum, Jeremy S and Robinson, Liam and Belov, Mikhail E and Ooi, Lezanne and Tortorella, Sara and Mitchell, Todd W and Ellis, Shane R},
  title = {MALDI-2-Enabled Oversampling for the Mass Spectrometry Imaging of Metabolites at Single-Cell Resolution},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  volume = {35},
  number = {11},
  pages = {2729--2742},
  doi = {10.1021/jasms.4c00241}
}