Position-Specific Oxygen Isotope Analysis in Inositol Phosphates by Using Electrospray Ionization-Quadrupole-Orbitrap Mass Spectrometry

Anthony J Hollenback, Deb P Jaisi iD

Journal of the American Society for Mass Spectrometry · 04.09.2024 · 35 (9) · 2176-2186

DOI: 10.1021/jasms.4c00210 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, online erschienen am 31.07.2024. Verfasst von Anthony J Hollenback und 1 weiteren Autor:innen. Beteiligte Einrichtung: Harker Interdisciplinary Science and Engineering Laboratory, Department of Plant and Soil Sciences, University of Delaware, Newark, Delaware 19716, U…. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Institute of Food and Agriculture, Division of Earth Sciences, University of Delaware.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional isotope-ratio mass spectrometry measurements obscure position-specific isotope distributions in molecular compounds because these measurements require an initial step that converts compounds into simple gases by combustion or pyrolysis. Here, we used electrospray ionization (ESI)-based Orbitrap mass spectrometry to measure oxygen isotope ratios in the phosphate and hydroxyl moieties of inositol phosphates. A thermal hydrolysis experiment was conducted using 18O-labeled water to examine the position-specific oxygen isotope exchange in inositol hexakisphosphate (IP6) as well as its hydrolysis products IP5, IP3, and PO3 fragments. Measurement precisions of the position-specific and molecular-average oxygen isotope values of inositol phosphates were better than ±1.1‰ and ±0.5‰, respectively. Under optimized ionization and Orbitrap parameters, this level of precision was obtained within 30 min of run time at 60 μM initial concentration of inositol phosphate. The ability to measure phosphate-specific oxygen isotopes in inositol phosphate enabled the quantification of isotope exchange, which did not occur in phosphate on IP6, IP5, IP3, and PO3 fragments, meaning that the change in isotopes should have resulted from hydroxyls in the ring. Isotope mass balance calculations corroborated that hydroxyl oxygens are derived from 18O-labeled water. With the observed sensitivity and precision achieved in this study, Orbitrap IRMS proved to be a promising tool for investigating the position-specific oxygen isotopes in organophosphorus compounds. These outcomes open up numerous potential applications that can expand our understanding of phosphorus cycling in the environment.

Autor:innen und Institutionen

  • Harker Interdisciplinary Science and Engineering Laboratory, Department of Plant and Soil Sciences, University of Delaware, Newark, Delaware 19716, United States.

ORCID-Profile: Deb P Jaisi

Förderung

  • National Institute of Food and Agriculture
  • Division of Earth Sciences
  • University of Delaware

Zitieren

APA

Hollenback, A. J., & Jaisi, D. P. (2024). Position-Specific Oxygen Isotope Analysis in Inositol Phosphates by Using Electrospray Ionization-Quadrupole-Orbitrap Mass Spectrometry. Journal of the American Society for Mass Spectrometry, 35(9), 2176-2186. https://doi.org/10.1021/jasms.4c00210

Vancouver

Hollenback AJ, Jaisi DP. Position-Specific Oxygen Isotope Analysis in Inositol Phosphates by Using Electrospray Ionization-Quadrupole-Orbitrap Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2024;35(9):2176-2186. doi:10.1021/jasms.4c00210

BibTeX
@article{Hollenback2024,
  author = {Hollenback, Anthony J and Jaisi, Deb P},
  title = {Position-Specific Oxygen Isotope Analysis in Inositol Phosphates by Using Electrospray Ionization-Quadrupole-Orbitrap Mass Spectrometry},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  volume = {35},
  number = {9},
  pages = {2176--2186},
  doi = {10.1021/jasms.4c00210}
}