Mobility-Assisted Pseudo-MS 3 Sequencing of Protein Ions
Journal of the American Society for Mass Spectrometry · 2024
DOI: 10.1021/jasms.4c00148 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, 2024. Verfasst von Katherine A Graham und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Nevada, 1664 N. Virginia Street, Reno, Nevada 89557, United States. Hauptthemen laut MEDLINE: Ion Mobility Spectrometry, Tandem Mass Spectrometry, Ions, Sequence Analysis, Protein. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, NIH HHS, NIH Office of the Director.
Themen: Mobilisation
Abstract (Originalsprache)
The sequencing of intact proteins within a mass spectrometer has many benefits but is frequently limited by the fact that tandem mass spectrometry (MS/MS) techniques often generate poor sequence coverages when applied to protein ions. To overcome this limitation, exotic MS/MS techniques that rely on lasers and radical chemistry have been developed. These techniques generate high sequence coverages, but they require specialized instrumentation, create products through multiple dissociation mechanisms, and often require long acquisition times. Recently, we demonstrated that protein ions can be dissociated in a trapped ion mobility spectrometry (TIMS) device prior to mobility separation in a commercial timsTOF. All generated product ions were distributed throughout the mobility dimension, and this separation enabled deconvolution of complex tandem mass spectra and could enable facile pseudo-MS3 interrogation of generated product ions with the downstream quadrupole and collision cell. A second activation step improves sequence coverage because the most labile bonds have been depleted during the first dissociation and subsequent dissociation events are more evenly distributed throughout the product ion backbone. In this work, we explore the potential of this mobility-assisted pseudo-MS3 (MAP) method on a commercial timsTOF and timsTOF Pro 2. We demonstrate that while MAP only generates 92% of the sequence coverage of the most effective MS/MS technique, it accomplished this feat in 1.5 min and could be facilely integrated with liquid chromatographic separations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, University of Nevada, 1664 N. Virginia Street, Reno, Nevada 89557, United States.
ORCID-Profile: Nicholas B Borotto
Förderung
- NIGMS NIH HHS
- NIH HHS
- NIH Office of the Director
- National Institute of General Medical Sciences
Zitieren
APA
Graham, K. A., Grisolia, V. J., & Borotto, N. B. (2024). Mobility-Assisted Pseudo-MS 3 Sequencing of Protein Ions. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.4c00148
Vancouver
Graham KA, Grisolia VJ, Borotto NB. Mobility-Assisted Pseudo-MS 3 Sequencing of Protein Ions. Journal of the American Society for Mass Spectrometry. 2024. doi:10.1021/jasms.4c00148
BibTeX
@article{Graham2024,
author = {Graham, Katherine A and Grisolia, Vincent J and Borotto, Nicholas B},
title = {Mobility-Assisted Pseudo-MS 3 Sequencing of Protein Ions},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2024},
doi = {10.1021/jasms.4c00148}
}
EUVIMED