PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data
Journal of the American Society for Mass Spectrometry · 2024-11-06 · 35 (11) · 2680-2689
DOI: 10.1021/jasms.4c00146 ↗At a glance
Journal article in Journal of the American Society for Mass Spectrometry, published online on 2024-07-16. Written by Andrea Harrison and 18 co-authors. Institution: Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States. Major MEDLINE topics: Software, Quality Control, Metabolomics, Mass Spectrometry. Cited 9 times so far (Crossref); 24 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, Environmental Molecular Sciences Laboratory, National Cancer Institute.
Abstract (original language)
Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, we describe and illustrate PeakQC's functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States.
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States.
- US Department of Energy Agile BioFoundry, Emeryville, California 94608, United States.
- Energy Processes & Materials Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States.
ORCID profiles: Yuqian Gao, Chaevien S Clendinen, Xueyun Zheng, Christopher R Anderton, Kyle R Pomraning, Kristin E Burnum-Johnson, Tao Liu, Aivett Bilbao
Funding
- NCI NIH HHS
- Environmental Molecular Sciences Laboratory
- National Cancer Institute
- Workforce Development for Teachers and Scientists
- Agile BioFoundry
Cite
APA
Harrison, A., Eder, J. G., Lalli, P. M., Munoz, N., Gao, Y., Clendinen, C. S., Orton, D. J., Zheng, X., Williams, S. M., Couvillion, S. P., Chu, R. K., Balasubramanian, V. K., Bhattacharjee, A., Anderton, C. R., Pomraning, K. R., Burnum-Johnson, K. E., Liu, T., Kyle, J. E., & Bilbao, A. (2024). PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data. Journal of the American Society for Mass Spectrometry, 35(11), 2680-2689. https://doi.org/10.1021/jasms.4c00146
Vancouver
Harrison A, Eder JG, Lalli PM, Munoz N, Gao Y, Clendinen CS, et al. PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data. Journal of the American Society for Mass Spectrometry. 2024;35(11):2680-2689. doi:10.1021/jasms.4c00146
BibTeX
@article{Harrison2024,
author = {Harrison, Andrea and Eder, Josie G and Lalli, Priscila M and Munoz, Nathalie and Gao, Yuqian and Clendinen, Chaevien S and Orton, Daniel J and Zheng, Xueyun and Williams, Sarah M and Couvillion, Sneha P and Chu, Rosalie K and Balasubramanian, Vimal K and Bhattacharjee, Arunima and Anderton, Christopher R and Pomraning, Kyle R and Burnum-Johnson, Kristin E and Liu, Tao and Kyle, Jennifer E and Bilbao, Aivett},
title = {PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2024},
volume = {35},
number = {11},
pages = {2680--2689},
doi = {10.1021/jasms.4c00146}
}
EUVIMED