EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Direct Identification of Intact Proteins Using a Low-Resolution Mass Spectrometer with CID n /ETnoD

Cheng-Yu Kuo, Yi-Feng Zheng, Wei-Chen Wang, Jie-Teng Toh, Yu-Ming Hsu, Han-Ju Chien, Chih-Jui Chang, Chien-Chen Lai iD

Journal of the American Society for Mass Spectrometry · 2024

DOI: 10.1021/jasms.4c00108 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2024. Written by Cheng-Yu Kuo and 7 co-authors. Institution: Institute of Molecular Biology, National Chung Hsing University, Taichung 402, Taiwan. Major MEDLINE topics: Myoglobin, Proteomics. Cited 2 times so far (Crossref); 31 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Chung-Hsing University, Asia University Hospital, Taichung Veterans General Hospital.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Over the past decades, proteomics has become increasingly important and a heavily discussed topic. The identification of intact proteins remains a major focus in this field. While most intact proteins are analyzed using high-resolution mass spectrometry, identifying them through low-resolution mass spectrometry continues to pose challenges. In our study, we investigated the capability of identifying various intact proteins using collision-induced dissociation (CID) and electron transfer without dissociation (ETnoD). Using myoglobin as our test protein, stable product ions were generated with CID, and the identities of the product ions were identified with ETnoD. ETnoD uses a short activation time (AcT, 5 ms) to create sequential charge-reduced precursor ion (CRI). The charges of the fragments and their sequences were determined with corresponding CRI. The product ions can be selected for subsequent CID (termed CIDn) combined with ETnoD for further sequence identification and validation. We refer to this method as CIDn/ETnoD. The use of a multistage CID activation (CIDn) and ETnoD protocol has been applied to several intact proteins to obtain multiple sequence identifications.

Subjects

MeSH terms (MEDLINE)

MyoglobinProteomicsAnimalsProteinsAmino Acid SequenceHorsesMass SpectrometryMolecular Sequence DataTandem Mass Spectrometry

Author keywords

CIDCharged-reduced precursor ionsETnoDIntact proteinLow-resolution mass spectrometry

Substances

MyoglobinProteins

Authors and institutions

  • Institute of Molecular Biology, National Chung Hsing University, Taichung 402, Taiwan.
  • Department of Biochemical Science and Technology, National Chiayi University, Chiayi 600, Taiwan.
  • Department of Molecular Biology and Human Genetics, Tzu Chi University, Hualien City 970, Taiwan.
  • Advanced Plant and Food Crop Biotechnology Center, National Chung Hsing University, Taichung 402, Taiwan.
  • Graduate Institute of Chinese Medical Science, China Medical University, Taichung 406, Taiwan.
  • Doctoral Program in Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan.

ORCID profiles: Chien-Chen Lai

Funding

  • National Chung-Hsing University
  • Asia University Hospital
  • Taichung Veterans General Hospital
  • National Science and Technology Council
  • Ministry of Education, Taiwan

Cite

APA

Kuo, C. Y., Zheng, Y. F., Wang, W. C., Toh, J. T., Hsu, Y. M., Chien, H. J., Chang, C. J., & Lai, C. C. (2024). Direct Identification of Intact Proteins Using a Low-Resolution Mass Spectrometer with CID n /ETnoD. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.4c00108

Vancouver

Kuo CY, Zheng YF, Wang WC, Toh JT, Hsu YM, Chien HJ, et al. Direct Identification of Intact Proteins Using a Low-Resolution Mass Spectrometer with CID n /ETnoD. Journal of the American Society for Mass Spectrometry. 2024. doi:10.1021/jasms.4c00108

BibTeX
@article{Kuo2024,
  author = {Kuo, Cheng-Yu and Zheng, Yi-Feng and Wang, Wei-Chen and Toh, Jie-Teng and Hsu, Yu-Ming and Chien, Han-Ju and Chang, Chih-Jui and Lai, Chien-Chen},
  title = {Direct Identification of Intact Proteins Using a Low-Resolution Mass Spectrometer with CID n /ETnoD},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  doi = {10.1021/jasms.4c00108}
}
Start for free →