Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, online erschienen am 29.04.2024. Verfasst von Min Tu und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Technology, Beijing Institute of Technology, Beijing 100081, P. R. China. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Beijing Institute of Technology, China Academy of Chinese Medical Sciences, Beijing Association for Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The sensitivity of the miniature mass spectrometer (mini-MS) is largely restricted by the ion transmission in rough vacuum region. Even though various "in-line" ion transfer devices have improved mini-MS sensitivity, the severe dynamic gas is still weakening the efficiency of ion transmission in this region. Inspired by the "off-axis" ion funnel design in the lab-scale mass spectrometers, a miniature orthogonal injection ion funnel (MO-IF) was developed in this study for the mini-MS with a continuous atmospheric pressure interface. Capable of directing injected ions by 90° and then transport them forward to the downstream skimmer, the MO-IF enabled the separation of ions from the dynamic gas flow jetted out of the inlet capillary. The key factors were optimized for the MO-IF, including the effects of RF amplitude, DC electric fields, and the position of the repeller. Under optimized conditions, the MO-IF minimized the negative effects of dynamic gas and improved the ion transmission efficiency by ∼2-fold in comparison with the in-line injection ion funnel. As a result, a lower limit of detection of 0.5 ng/mL were obtained with good linearity for hypaconitine. Additionally, the MO-IF further decreased the buffer gas pressure in the second vacuum chamber and improved the mass resolution by 1.1-1.5 times at different scan rates.

Autor:innen und Institutionen

  • School of Medical Technology, Beijing Institute of Technology, Beijing 100081, P. R. China.

ORCID-Profile: Wei Xu, Yanbing Zhai

Förderung

  • Beijing Institute of Technology
  • China Academy of Chinese Medical Sciences
  • Beijing Association for Science and Technology

Zitieren

APA

Tu, M., Xu, W., & Zhai, Y. (2024). A Miniature Orthogonal Injection Ion Funnel (MO-IF) Providing Enhanced Performance for the Miniature Mass Spectrometer. Journal of the American Society for Mass Spectrometry, 35(6), 1363-1369. https://doi.org/10.1021/jasms.4c00100

Vancouver

Tu M, Xu W, Zhai Y. A Miniature Orthogonal Injection Ion Funnel (MO-IF) Providing Enhanced Performance for the Miniature Mass Spectrometer. Journal of the American Society for Mass Spectrometry. 2024;35(6):1363-1369. doi:10.1021/jasms.4c00100

BibTeX
@article{Tu2024,
  author = {Tu, Min and Xu, Wei and Zhai, Yanbing},
  title = {A Miniature Orthogonal Injection Ion Funnel (MO-IF) Providing Enhanced Performance for the Miniature Mass Spectrometer},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  volume = {35},
  number = {6},
  pages = {1363--1369},
  doi = {10.1021/jasms.4c00100}
}