EUVIMEDEUVIMED entdecken
Crossref

Double-Helix Electrode Ion Funnel: A New Ion Funnel Design with an Extended Mass Range

Bin Wu, Xingliang He, Xing Guo, Fulong Deng, Hongen Sun, Yi Pan, Yixiang Duan, Zhongjun Zhao iD

Analytical Chemistry · 28.01.2025 · 97 (3) · 1612-1619

DOI: 10.1021/acs.analchem.4c04414 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 13.01.2025. Verfasst von Bin Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Research Center of Analytical Instrumentation, School of Mechanical Engineering, Sichuan University, Chengdu 610065, People's Republic of China. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Science and Technology Department of Sichuan Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of an atmospheric pressure interface (API) with a high ion transfer efficiency and wide mass range is advantageous for the performance improvement of mass spectrometry (MS) instruments. In this work, a novel ion guide, namely, the double-helix electrode ion funnel (DHE-IF), has been developed to enhance the ion transmission over a wide mass range in the rough vacuum region. The DHE-IF consists of two funnel-shaped helix electrodes. There are almost no potential "traps" along the central axis of DHE-IF due to the continuous double-helix electrode structure compared to the stacked ring ion funnel. The electrode design of the DHE-IF assembly was guided by ion trajectory simulations. After being fabricated, DHE-IF was integrated into an ESI-TOF-MS platform for tests. A conventional stacked ring ion funnel (IF) was also tested for comparison. The experimental results showed that DHE-IF extended the transmission window of the IF and improved the efficiency of the simultaneous transferring of low and medium m/z ions. In addition, the intensities of caffeine ions (m/z = 195) and reserpine ions (m/z = 609) were enhanced by more than 50% and 10%, respectively. These values were compared with the results obtained by the IF. The DHE-IF is expected to be widely used as an ion import device in MS instruments, which is due to its improved performance and advantages in, e.g., integration and power supply design.

Autor:innen und Institutionen

  • Research Center of Analytical Instrumentation, School of Mechanical Engineering, Sichuan University, Chengdu 610065, People's Republic of China.
  • Institute of Chemistry, National Institute of Measurement and Testing Technology, Chengdu 610021, People's Republic of China.
  • Aliben Science & Technology, Chengdu 611930, People's Republic of China.

ORCID-Profile: Zhongjun Zhao

Förderung

  • Science and Technology Department of Sichuan Province

Zitieren

APA

Wu, B., He, X., Guo, X., Deng, F., Sun, H., Pan, Y., Duan, Y., & Zhao, Z. (2025). Double-Helix Electrode Ion Funnel: A New Ion Funnel Design with an Extended Mass Range. Analytical Chemistry, 97(3), 1612-1619. https://doi.org/10.1021/acs.analchem.4c04414

Vancouver

Wu B, He X, Guo X, Deng F, Sun H, Pan Y, et al. Double-Helix Electrode Ion Funnel: A New Ion Funnel Design with an Extended Mass Range. Analytical Chemistry. 2025;97(3):1612-1619. doi:10.1021/acs.analchem.4c04414

BibTeX
@article{Wu2025,
  author = {Wu, Bin and He, Xingliang and Guo, Xing and Deng, Fulong and Sun, Hongen and Pan, Yi and Duan, Yixiang and Zhao, Zhongjun},
  title = {Double-Helix Electrode Ion Funnel: A New Ion Funnel Design with an Extended Mass Range},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {3},
  pages = {1612--1619},
  doi = {10.1021/acs.analchem.4c04414}
}