EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Increasing Isolation Efficiency Using a Segmented Quadrupole Mass Filter Operated with Rectangular Waveforms

Robert L Schrader iD, Gordon A Anderson, David H Russell iD

Journal of the American Society for Mass Spectrometry · 2024-06-05 · 35 (6) · 1237-1244

DOI: 10.1021/jasms.4c00051 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2024-04-30. Written by Robert L Schrader and 2 co-authors. Institution: Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States. Cited 8 times so far (Crossref); 48 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIGMS NIH HHS, National Institute of General Medical Sciences.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

The performance of a segmented quadrupole mass filter operated with rectangular waveforms and capacitively coupled rectangular waveforms applied to the prefilters was examined on a home-built quadrupole-Orbitrap platform. For peak widths of 50 m/z, 100% isolation efficiency was achieved, which fell to approximately 20% for 5 m/z peak width for a rectangular waveform of 150 V0-p. Due to a small exit aperture following the mass filter, peak structure was observed in both experimental peak shapes and those simulated using SIMION. A larger radius quadrupole was examined and achieved similar performance. While the segmented quadrupole does remove the defocusing effects of the fringing fields, the ion beam is only slightly refocused due to the low RF voltage which limits achievable gains in isolation efficiency.

Subjects

Author keywords

Brubaker prefiltersOrbitrap mass spectrometrydigital mass filterquadrupole mass spectrometry

Authors and institutions

  • Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States.
  • GAA Custom Electronics, Kennewick, Washington 99338, United States.

ORCID profiles: Robert L Schrader, David H Russell

Funding

  • NIGMS NIH HHS
  • National Institute of General Medical Sciences

Cite

APA

Schrader, R. L., Anderson, G. A., & Russell, D. H. (2024). Increasing Isolation Efficiency Using a Segmented Quadrupole Mass Filter Operated with Rectangular Waveforms. Journal of the American Society for Mass Spectrometry, 35(6), 1237-1244. https://doi.org/10.1021/jasms.4c00051

Vancouver

Schrader RL, Anderson GA, Russell DH. Increasing Isolation Efficiency Using a Segmented Quadrupole Mass Filter Operated with Rectangular Waveforms. Journal of the American Society for Mass Spectrometry. 2024;35(6):1237-1244. doi:10.1021/jasms.4c00051

BibTeX
@article{Schrader2024,
  author = {Schrader, Robert L and Anderson, Gordon A and Russell, David H},
  title = {Increasing Isolation Efficiency Using a Segmented Quadrupole Mass Filter Operated with Rectangular Waveforms},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  volume = {35},
  number = {6},
  pages = {1237--1244},
  doi = {10.1021/jasms.4c00051}
}
Start for free →