EUVIMEDScopri EUVIMED
Open access · CC BY 4.0

Improved Detection of Tryptic Peptides from Tissue Sections Using Desorption Electrospray Ionization Mass Spectrometry Imaging

Heather Bottomley, Jonathan Phillips iD, Philippa Hart

Journal of the American Society for Mass Spectrometry · 2024

DOI: 10.1021/jasms.4c00006 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2024. Written by Heather Bottomley and 2 co-authors. Institution: Living Systems Institute, Department of Biosciences, University of Exeter, Stocker Road, Exeter EX4 4QD, U.K. Major MEDLINE topics: Brain Chemistry, Spectrometry, Mass, Electrospray Ionization. Cited 11 times so far (Crossref); 58 references. The full text is freely available (open access, CC BY 4.0). Funded by: Wellcome Trust, Medical Research Council.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

DESI-MSI is an ambient ionization technique used frequently for the detection of lipids, small molecules, and drug targets. Until recently, DESI had only limited use for the detection of proteins and peptides due to the setup and needs around deconvolution of data resulting in a small number of species being detected at lower spatial resolution. There are known differences in the ion species detected using DESI and MALDI for nonpeptide molecules, and here, we identify that this extends to proteomic species. DESI MS images were obtained for tissue sections of mouse and rat brain using a precommercial heated inlet (approximately 450 °C) to the mass spectrometer. Ion mobility separation resolved spectral overlap of peptide ions and significantly improved the detection of multiply charged species. The images acquired were of pixel size 100 μm (rat brain) and 50 μm (mouse brain), respectively. Observed tryptic peptides were filtered against proteomic target lists, generated by LC–MS, enabling tentative protein assignment for each peptide ion image. Precise localizations of peptide ions identified by DESI and MALDI were found to be comparable. Some spatially localized peptides ions were observed in DESI that were not found in the MALDI replicates, typically, multiply charged species with a low mass to charge ratio. This method demonstrates the potential of DESI-MSI to detect large numbers of tryptic peptides from tissue sections with enhanced spatial resolution when compared to previous DESI-MSI studies.

Subjects

MeSH terms (MEDLINE)

Brain ChemistrySpectrometry, Mass, Electrospray IonizationAnimalsMiceRatsPeptidesBrainProteomicsSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationTrypsinPeptide Fragments

Substances

PeptidesTrypsinPeptide Fragments

Authors and institutions

  • Living Systems Institute, Department of Biosciences, University of Exeter, Stocker Road, Exeter EX4 4QD, U.K.
  • Medicines Discovery Catapult, Alderley Park, Block 35, Mereside, Macclesfield SK10 4ZF, U.K.

ORCID profiles: Jonathan Phillips

Funding

  • Wellcome Trust
  • Medical Research Council

Cite

APA

Bottomley, H., Phillips, J., & Hart, P. (2024). Improved Detection of Tryptic Peptides from Tissue Sections Using Desorption Electrospray Ionization Mass Spectrometry Imaging. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.4c00006

Vancouver

Bottomley H, Phillips J, Hart P. Improved Detection of Tryptic Peptides from Tissue Sections Using Desorption Electrospray Ionization Mass Spectrometry Imaging. Journal of the American Society for Mass Spectrometry. 2024. doi:10.1021/jasms.4c00006

BibTeX
@article{Bottomley2024,
  author = {Bottomley, Heather and Phillips, Jonathan and Hart, Philippa},
  title = {Improved Detection of Tryptic Peptides from Tissue Sections Using Desorption Electrospray Ionization Mass Spectrometry Imaging},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  doi = {10.1021/jasms.4c00006}
}
Start for free →