Selective Sampling to and Desorption from Single Solid-Phase Microextraction Arrow Fiber for Replicative and Quantitative Analysis
Journal of the American Society for Mass Spectrometry · 06.03.2024 · 35 (3) · 527-533
DOI: 10.1021/jasms.3c00394 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, online erschienen am 06.02.2024. Verfasst von G Asher Newsome und 2 weiteren Autor:innen. Beteiligte Einrichtung: Smithsonian Institution Museum Conservation Institute, Suitland, Maryland 20746, United States. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Smithsonian Institution.
Abstract (Originalsprache)
New analytical functionality is demonstrated with an enclosed interface that joins a solid phase microextraction (SPME) device, a direct analysis in real time (DART) probe, and a high-resolution mass spectrometer. With a single 20 mm long SPME Arrow, the interface is able to perform five discrete DART analyses on different areas of the same fiber in 1 min of practical operation time. Three-fiber replicates for 15 runs total produce 15% or better center of variance (CV) values for both volatile headspace sampling and direct immersion sampling of a solvated analyte. Chemometric analysis of rapidly acquired headspace data is able to distinguish volatile profiles. Selective desorption within the interface also confers the ability to selectively sample to discrete areas of a fiber, and three different headspace samples or five different liquid samples can be acquired and differentiated with one Arrow. A five-point standard addition curve is constructed to measure the concentration of the solvated analyte. Unmodified commercial components of the analysis system include the fiber itself, the Orbitrap and AccuTOF mass spectrometer platforms, and the conditioning gas chromatograph inlet. Machine diagrams for the SPME-DART interface and Arrow fiber holder are included.
Autor:innen und Institutionen
- Smithsonian Institution Museum Conservation Institute, Suitland, Maryland 20746, United States.
- Smithsonian National Museum of the American Indian, Suitland, Maryland 20746, United States.
- JEOL USA Inc, Peabody, Massachusetts 01960, United States.
ORCID-Profile: G Asher Newsome, Erin R Birdsall, Robert B Cody
Förderung
- Smithsonian Institution
Zitieren
APA
Newsome, G. A., Birdsall, E. R., & Cody, R. B. (2024). Selective Sampling to and Desorption from Single Solid-Phase Microextraction Arrow Fiber for Replicative and Quantitative Analysis. Journal of the American Society for Mass Spectrometry, 35(3), 527-533. https://doi.org/10.1021/jasms.3c00394
Vancouver
Newsome GA, Birdsall ER, Cody RB. Selective Sampling to and Desorption from Single Solid-Phase Microextraction Arrow Fiber for Replicative and Quantitative Analysis. Journal of the American Society for Mass Spectrometry. 2024;35(3):527-533. doi:10.1021/jasms.3c00394
BibTeX
@article{Newsome2024,
author = {Newsome, G Asher and Birdsall, Erin R and Cody, Robert B},
title = {Selective Sampling to and Desorption from Single Solid-Phase Microextraction Arrow Fiber for Replicative and Quantitative Analysis},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2024},
volume = {35},
number = {3},
pages = {527--533},
doi = {10.1021/jasms.3c00394}
}
EUVIMED