EUVIMEDEUVIMED entdecken
Crossref

Effect of pH on In-Electrospray Hydrogen/Deuterium Exchange of Carbohydrates and Peptides

Jacob B Hatvany iD, O Tara Liyanage, Elyssia S Gallagher iD

Journal of the American Society for Mass Spectrometry · 2024

DOI: 10.1021/jasms.3c00341 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, 2024. Verfasst von Jacob B Hatvany und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry & Biochemistry, Baylor University, One Bear Place #97348, Waco, Texas 76798, United States. Hauptthemen laut MEDLINE: Hydrogen, Deuterium Exchange Measurement. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: Division of Chemistry, Welch Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Carbohydrates are critical for cellular functions as well as an important class of metabolites. Characterizing carbohydrate structures is a difficult analytical challenge due to the presence of isomers. In-electrospray hydrogen/deuterium exchange mass spectrometry (in-ESI HDX-MS) is a method of HDX that samples the solvated structure of carbohydrates during the ESI process and requires little to no instrument modification. Traditionally, solution-phase HDX is utilized with proteins to sample conformational differences, and pH is a critical parameter to monitor and control due to the presence of both acid- and base-catalyzed mechanisms of exchange. For In-ESI HDX, the pH surrounding the analyte changes before and during labeling, which has the potential to affect the rate of labeling for analytes. Herein, we alter the pH of spray solutions containing model carbohydrates and peptides, perform in-ESI HDX-MS, and characterize the deuterium uptake trends. Varying pH results in altered D uptake, though the overall trends differ from the expected bulk-solution trends due to the electrospray process. These findings show the utility of varying pH prior to in-ESI HDX-MS for establishing different extents of HDX as well as distinguishing labile functional groups that are present in different analytes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrogenDeuterium Exchange MeasurementDeuteriumPeptidesCarbohydratesHexosesHydrogen-Ion Concentration

Substanzen

HydrogenDeuteriumPeptidesCarbohydratesHexoses

Autor:innen und Institutionen

  • Department of Chemistry & Biochemistry, Baylor University, One Bear Place #97348, Waco, Texas 76798, United States.

ORCID-Profile: Jacob B Hatvany, Elyssia S Gallagher

Förderung

  • Division of Chemistry
  • Welch Foundation

Zitieren

APA

Hatvany, J. B., Liyanage, O. T., & Gallagher, E. S. (2024). Effect of pH on In-Electrospray Hydrogen/Deuterium Exchange of Carbohydrates and Peptides. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00341

Vancouver

Hatvany JB, Liyanage OT, Gallagher ES. Effect of pH on In-Electrospray Hydrogen/Deuterium Exchange of Carbohydrates and Peptides. Journal of the American Society for Mass Spectrometry. 2024. doi:10.1021/jasms.3c00341

BibTeX
@article{Hatvany2024,
  author = {Hatvany, Jacob B and Liyanage, O Tara and Gallagher, Elyssia S},
  title = {Effect of pH on In-Electrospray Hydrogen/Deuterium Exchange of Carbohydrates and Peptides},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  doi = {10.1021/jasms.3c00341}
}
Kostenlos starten →