Novel LC-MS/MS Method for Simultaneous Determination of Monoamine Neurotransmitters and Metabolites in Human Samples
Journal of the American Society for Mass Spectrometry · 2024-04-03 · 35 (4) · 663-673
DOI: 10.1021/jasms.3c00326 ↗At a glance
Journal article in Journal of the American Society for Mass Spectrometry, published online on 2024-03-06. Written by Dileshwar Kumar and 2 co-authors. Institution: Division of Food Safety, Indian Council of Medical Research, National Institute of Nutrition, Jamai-Osmania, Hyderabad, Telangana 500007, India. Major MEDLINE topics: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry. Cited 29 times so far (Crossref); 50 references. Funded by: Council of Scientific and Industrial Research, India, Department of Health Research, India.
Abstract (original language)
For the simultaneous determination of monoamine neurotransmitters (NTs) like dopamine, serotonin, noradrenaline, and epinephrine, and their metabolites (metanephrine, normetanephrine, 3-methoxytyramine, vanillylmandelic acid, 3,4-dihydroxyphenylacetic acid, homovanillic acid, and 5-hydroxyindoleacetic acid), a robust liquid chromatography method coupled with tandem mass spectrometry (LC-MS/MS) was introduced as the analytical method. This analytical method proved to be accurate for the simultaneous measurement of the amounts of 11 NTs and their metabolites in biological samples. The method proved to be more efficient and better than the previously reported method in terms of precision, recovery, sample requirement, and extraction procedure. The reported method requires only 100 μL of blood and 200 μL of urine, and the extraction procedure requires acetonitrile precipitation, filtration, drying, and reconstitution in water. The separation of all analytes was performed on an C18 column (4.6 mm × 150 mm and 1.8 μm). A 10 min gradient elution program with a mobile phase consisting of phase A (0.2% formic acid in water) and phase B (methanol) was used. The positive ionization mode was used for the detection of all analytes in multiple reaction monitoring (MRM). The proposed method was validated with an internal standard and yielded lower limits of detection and quantification ranges of 0.0182-0.0797 ng/mL and 0.0553-0.2415 ng/mL, respectively, with a good linearity (R2) between 0.9959 and 0.9994. The recoveries ranged from 73.37% to 116.63% in blood and from 80.9% to 115.33% in urine. For the NTs and metabolites, the intra- and interday % CV were 0.24-9.36 and 0.85-9.67, respectively. The developed LC-MS/MS method was successfully used for the determination of trace amounts of endogenous compounds in human blood and urine samples.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Division of Food Safety, Indian Council of Medical Research, National Institute of Nutrition, Jamai-Osmania, Hyderabad, Telangana 500007, India.
- Department of Biochemistry Osmania University, Hyderabad, Telangana 500007, India.
ORCID profiles: Sukesh Narayan Sinha
Funding
- Council of Scientific and Industrial Research, India
- Department of Health Research, India
Cite
APA
Kumar, D., Sinha, S. N., & Gouda, B. (2024). Novel LC-MS/MS Method for Simultaneous Determination of Monoamine Neurotransmitters and Metabolites in Human Samples. Journal of the American Society for Mass Spectrometry, 35(4), 663-673. https://doi.org/10.1021/jasms.3c00326
Vancouver
Kumar D, Sinha SN, Gouda B. Novel LC-MS/MS Method for Simultaneous Determination of Monoamine Neurotransmitters and Metabolites in Human Samples. Journal of the American Society for Mass Spectrometry. 2024;35(4):663-673. doi:10.1021/jasms.3c00326
BibTeX
@article{Kumar2024,
author = {Kumar, Dileshwar and Sinha, Sukesh Narayan and Gouda, Balaji},
title = {Novel LC-MS/MS Method for Simultaneous Determination of Monoamine Neurotransmitters and Metabolites in Human Samples},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2024},
volume = {35},
number = {4},
pages = {663--673},
doi = {10.1021/jasms.3c00326}
}
EUVIMED