EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Hydrophilic Interaction Liquid Chromatography at Subzero Temperature for Hydrogen–Deuterium Exchange Mass Spectrometry

Kyle W Anderson iD, Jeffrey W Hudgens iD

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.3c00243 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Kyle W Anderson and 1 co-authors. Institution: Bioprocess Measurements Group, Biomolecular Measurement Division, National Institute of Standards and Technology, Rockville, Maryland 20850, United S…. Major MEDLINE topics: Deuterium Exchange Measurement, Chromatography, Reverse-Phase. Cited 9 times so far (Crossref); 67 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Intramural NIST DOC.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Chromatographic separations at subzero temperature significantly improve the precision of back-exchange-corrected hydrogen-deuterium exchange mass spectrometry (HDX-MS) determinations. Our previously reported dual-enzyme HDX-MS analysis instrument used reversed phase liquid chromatography (RPLC) at -30 °C, but high backpressures limited flow rates and required materials and equipment rated for very high pressures. Here, we report the design and performance of a dual-enzyme HDX-MS analysis instrument comprising a RPLC trap column and a hydrophilic interaction liquid chromatography (HILIC) analytical column in a two-dimensional RPLC-HILIC configuration at subzero temperature. During operation at -30 °C, the HILIC column manifests greatly reduced backpressure, which enables faster analytical flow rates and the use of materials rated for lower maximum pressures. The average peptide eluted from a HILIC column during a 40 min gradient at -30 °C contained ≈13% more deuterium than peptides eluted from a tandem RPLC-RPLC apparatus using a conventional 8 min gradient at 0 °C. A subset of peptides eluted from the HILIC apparatus contained ≈24% more deuterium.

Subjects

MeSH terms (MEDLINE)

Deuterium Exchange MeasurementChromatography, Reverse-PhaseDeuteriumTemperatureChromatography, LiquidMass SpectrometryPeptidesHydrogenHydrophobic and Hydrophilic Interactions

Substances

DeuteriumPeptidesHydrogen

Authors and institutions

  • Bioprocess Measurements Group, Biomolecular Measurement Division, National Institute of Standards and Technology, Rockville, Maryland 20850, United States.
  • Institute for Bioscience and Biotechnology Research, 9600 Gudelsky Drive, Rockville, Maryland 20850, United States.

ORCID profiles: Kyle W Anderson, Jeffrey W Hudgens

Funding

  • Intramural NIST DOC

Cite

APA

Anderson, K. W., & Hudgens, J. W. (2023). Hydrophilic Interaction Liquid Chromatography at Subzero Temperature for Hydrogen–Deuterium Exchange Mass Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00243

Vancouver

Anderson KW, Hudgens JW. Hydrophilic Interaction Liquid Chromatography at Subzero Temperature for Hydrogen–Deuterium Exchange Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00243

BibTeX
@article{Anderson2023,
  author = {Anderson, Kyle W and Hudgens, Jeffrey W},
  title = {Hydrophilic Interaction Liquid Chromatography at Subzero Temperature for Hydrogen–Deuterium Exchange Mass Spectrometry},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.3c00243}
}
Start for free →