EUVIMEDOpdag EUVIMED
Open access

Collision Induced Unfolding Enables the Quantitation of Isomass Biotherapeutics in Complex Biological Matrices

Brock R Juliano, Brandon T Ruotolo iD

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.3c00234 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Brock R Juliano and 1 co-authors. Institution: Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States. Major MEDLINE topics: Ion Mobility Spectrometry, Protein Unfolding. Cited 6 times so far (Crossref); 47 references. The full text is freely available in PubMed Central. Funded by: NIGMS NIH HHS, National Institute of General Medical Sciences.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Quantitative mass spectrometry has been widely used to evaluate the concentrations of molecules within a variety of biological matrices. Typically, such quantitative mass spectrometry analyses are predicated upon the production of mass-resolved precursor or fragment ions, leading to challenges surrounding the quantification of isomeric or conformationally distinct analytes. As such, new approaches are required for the label-free quantification of isomass proteins. Native ion-mobility MS (nIM-MS) in combination with collision induced unfolding (CIU) is a potentially enabling approach for such quantitative mass spectrometry methods as the technique can rapidly separate and detect many biomacromolecule isoforms. CIU uses collisional activation to capture the unfolding trajectory of ions in the gas phase, producing different intermediate structures that can be leveraged to distinguish protein structures that exhibit identical sizes at lower energies. Here we describe the deployment of quantitative CIU methodology to measure the concentrations of isomass pairs of biotherapeutics and sequence homologues in both standard and biological matrices. Our results cover three antibody pairs and include examples of mixed therapies where multiple biologics are commonly provided to patients. In all cases, CIU enables the production of resolved features for each antibody mixture probed, producing calibration curves with correlation coefficients ranging from 0.92 to 0.99, limits of detection ranging from 300 to 5000 nM and sensitivities ranging from 8.7 × 10-5 nM-1 to 6 × 10-3 μM-1. We conclude our report by projecting the future utility of CIU-enabled quantitative MS methods.

Subjects

MeSH terms (MEDLINE)

Ion Mobility SpectrometryProtein UnfoldingHumansBiological ProductsMass SpectrometryProtein IsoformsAntibodies, Monoclonal

Substances

Biological ProductsProtein IsoformsAntibodies, Monoclonal

Authors and institutions

  • Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.

ORCID profiles: Brandon T Ruotolo

Funding

  • NIGMS NIH HHS
  • National Institute of General Medical Sciences

Cite

APA

Juliano, B. R., & Ruotolo, B. T. (2023). Collision Induced Unfolding Enables the Quantitation of Isomass Biotherapeutics in Complex Biological Matrices. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00234

Vancouver

Juliano BR, Ruotolo BT. Collision Induced Unfolding Enables the Quantitation of Isomass Biotherapeutics in Complex Biological Matrices. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00234

BibTeX
@article{Juliano2023,
  author = {Juliano, Brock R and Ruotolo, Brandon T},
  title = {Collision Induced Unfolding Enables the Quantitation of Isomass Biotherapeutics in Complex Biological Matrices},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.3c00234}
}
Start for free →