A Graphene-Coated Silicon Wafer Plate Improves the Sensitivity and Reproducibility of MALDI-TOF MS Analysis of Proteins
Journal of the American Society for Mass Spectrometry · 06.09.2023 · 34 (9) · 2034-2042
DOI: 10.1021/jasms.3c00201 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, online erschienen am 04.08.2023. Verfasst von Yoon Kyung Choi und 3 weiteren Autor:innen. Beteiligte Einrichtung: R&D Center for Clinical Mass Spectrometry, Seegene Medical Foundation, Seongdong-gu, Seoul 04805, Korea. Hauptthemen laut MEDLINE: Graphite. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 46 Literaturangaben.
Abstract (Originalsprache)
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used to analyze small and large molecules. However, proteins are difficult to analyze with MALDI-TOF MS in clinical applications because of their low ionization efficiency and heterogeneous crystallization with the matrix on the sample spots. Here, we investigate the potential of a customized graphene-coated silicon wafer (G/SiO2) plate for MALDI-TOF MS analysis of a clinically important protein, KPC-2, in comparison with a conventional stainless steel (SUS) plate. Our results demonstrate that the G/SiO2 plate outperforms the SUS plate in terms of sensitivity, reproducibility, and mass accuracy/precision across a wide range of molecular weights, even with highly complex samples. Furthermore, a five-day robustness test confirms the practical applicability of the G/SiO2 plate for the reliable identification of target protein(s) in MALDI-TOF MS analysis. Overall, our findings suggest that the use of the G/SiO2 plate holds great potential for improving the sensitivity and reproducibility of MALDI-TOF MS analysis for the identification of proteins, making it a promising tool for clinical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- R&D Center for Clinical Mass Spectrometry, Seegene Medical Foundation, Seongdong-gu, Seoul 04805, Korea.
ORCID-Profile: Dong Huey Cheon, Je-Hyun Baek
Zitieren
APA
Choi, Y. K., Cheon, D. H., Yang, W. S., & Baek, J. H. (2023). A Graphene-Coated Silicon Wafer Plate Improves the Sensitivity and Reproducibility of MALDI-TOF MS Analysis of Proteins. Journal of the American Society for Mass Spectrometry, 34(9), 2034-2042. https://doi.org/10.1021/jasms.3c00201
Vancouver
Choi YK, Cheon DH, Yang WS, Baek JH. A Graphene-Coated Silicon Wafer Plate Improves the Sensitivity and Reproducibility of MALDI-TOF MS Analysis of Proteins. Journal of the American Society for Mass Spectrometry. 2023;34(9):2034-2042. doi:10.1021/jasms.3c00201
BibTeX
@article{Choi2023,
author = {Choi, Yoon Kyung and Cheon, Dong Huey and Yang, Won Suk and Baek, Je-Hyun},
title = {A Graphene-Coated Silicon Wafer Plate Improves the Sensitivity and Reproducibility of MALDI-TOF MS Analysis of Proteins},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2023},
volume = {34},
number = {9},
pages = {2034--2042},
doi = {10.1021/jasms.3c00201}
}
EUVIMED