Matrix-Enhanced SIMS: The Influence of Primary Ion Species and Cluster Size on Ion Yield and Ion Yield Enhancement of Lipids

Thorsten Adolphs iD, Marcel Heeger, Florian Bosse, Bart Jan Ravoo iD, Richard E Peterson, Heinrich F Arlinghaus, Bonnie J Tyler iD

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.3c00173 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Thorsten Adolphs and 6 co-authors. Institution: Institute of Physics, Westfälische Wilhelms-Universität, Wilhelm-Klemm-Straße 10, 48149 Münster, Germany. Major MEDLINE topics: Spectrometry, Mass, Secondary Ion, Lipids. Cited 12 times so far (Crossref); 31 references.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Time-of-flight secondary ion mass spectrometry is one of the most promising techniques for label-free analysis of biomolecules with nanoscale spatial resolution. However, high-resolution imaging of larger biomolecules such as phospholipids and peptides is often hampered by low yields of molecular ions. Matrix-enhanced SIMS (ME-SIMS), in which an organic matrix is added to the sample, is one promising approach to enhancing the ion yield for biomolecules. Optimizing this approach has, however, been challenging because the processes involved in increasing the ion yield in ME-SIMS are not yet fully understood. In this work, the matrix α-cyano-4-hydroxycinnamic acid (HCCA) has been combined with cluster primary ion analysis to better understand the roles of proton donation and reduced fragmentation on lipid molecule ion yield. A model system consisting of 1:100 mol ratio dipalmitoylphosphatidylcholine (DPPC) in HCCA as well as an HCCA-coated mouse brain cryosection have been studied using a range of Bi and Ar cluster ions. Although the molecular ion yield increased with an increase in cluster ion size, the enhancement of the signals from intact lipid molecules decreased with an increase in cluster ion size for both the model system and the mouse brain. Additionally, in both systems, protonated molecular ions were significantly more enhanced than sodium and potassium cationized molecules for all of the primary ions utilized. For the model system, the DPPC molecular ion yield was increased by more than an order of magnitude for all of the primary ions studied, and fragmentation of DPPC was dramatically reduced. However, on the brain sample, even though the HCCA matrix reduced DPPC fragmentation for all of the primary ions studied, the matrix coating suppressed the ion yield for some lipids when the larger cluster primary ions were employed. This indicated insufficient migration of the lipids into the matrix coating, so that dilution by the matrix overpowered the enhancement effect. This study provides strong evidence that the HCCA matrix both enhances protonation and reduces fragmentation. For imaging applications, the ability of the analytes to migrate to the surface of the matrix coating is also a critical factor for useful signal enhancement. This work demonstrates that the HCCA matrix provides a softer desorption environment when using Bi cluster ions than that obtained using the large gas cluster ions studied alone, indicating the potential for improved high spatial resolution imaging with ME-SIMS.

Subjects

MeSH terms (MEDLINE)

Spectrometry, Mass, Secondary IonLipidsAnimalsMiceIonsCoumaric Acids1,2-DipalmitoylphosphatidylcholineBrain ChemistryBrain

Substances

IonsLipidsCoumaric Acids1,2-Dipalmitoylphosphatidylcholinealpha-cyano-4-hydroxycinnamate

Authors and institutions

  • Institute of Physics, Westfälische Wilhelms-Universität, Wilhelm-Klemm-Straße 10, 48149 Münster, Germany.
  • Center for Soft Nanoscience (SoN), Westfälische Wilhelms-Universität, Busso-Peus-Straße 10, 48149 Münster, Germany.
  • Organic Chemistry Institute, Westfälische Wilhelms-Universität, Corrensstrasse 36, 48149 Münster, Germany.

ORCID profiles: Thorsten Adolphs, Bart Jan Ravoo, Bonnie J Tyler

Cite

APA

Adolphs, T., Heeger, M., Bosse, F., Ravoo, B. J., Peterson, R. E., Arlinghaus, H. F., & Tyler, B. J. (2023). Matrix-Enhanced SIMS: The Influence of Primary Ion Species and Cluster Size on Ion Yield and Ion Yield Enhancement of Lipids. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00173

Vancouver

Adolphs T, Heeger M, Bosse F, Ravoo BJ, Peterson RE, Arlinghaus HF, et al. Matrix-Enhanced SIMS: The Influence of Primary Ion Species and Cluster Size on Ion Yield and Ion Yield Enhancement of Lipids. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00173

BibTeX
@article{Adolphs2023,
  author = {Adolphs, Thorsten and Heeger, Marcel and Bosse, Florian and Ravoo, Bart Jan and Peterson, Richard E and Arlinghaus, Heinrich F and Tyler, Bonnie J},
  title = {Matrix-Enhanced SIMS: The Influence of Primary Ion Species and Cluster Size on Ion Yield and Ion Yield Enhancement of Lipids},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.3c00173}
}
Start for free →