Detecting Hexafluoroisopropanol Using Soft Chemical Ionization Mass Spectrometry and Analytical Applications to Exhaled Breath
Journal of the American Society for Mass Spectrometry · 2023
DOI: 10.1021/jasms.3c00042 ↗At a glance
Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Florentin Weiss and 9 co-authors. Institution: Institute for Breath Research, Universität Innsbruck, Innrain 66, A-6020 Innsbruck, Austria. Major MEDLINE topics: Gases, Nitrogen. Cited 10 times so far (Crossref); 43 references. The full text is freely available (open access, CC BY 4.0). Funded by: ?sterreichische Forschungsf?rderungsgesellschaft, Universit?t Innsbruck, Horizon 2020 Framework Programme.
Abstract (original language)
Here we explore the potential use of proton transfer reaction/selective reagent ion-time-of-flight-mass spectrometry (PTR/SRI-ToF-MS) to monitor hexafluoroisopropanol (HFIP) in breath. Investigations of the reagent ions H3O+, NO+, and O2+• are reported using dry (relative humidity (rH) ≈ 0%) and humid (rH ≈ 100%)) nitrogen gas containing traces of HFIP, i.e., divorced from the complex chemical environment of exhaled breath. HFIP shows no observable reaction with H3O+ and NO+, but it does react efficiently with O2+• via dissociative charge transfer resulting in CHF2+, CF3+, C2HF2O+, and C2H2F3O+. A minor competing hydride abstraction channel results in C3HF6O+ + HO2• and, following an elimination of HF, C3F5O+. There are two issues associated with the use of the three dominant product ions of HFIP, CHF2+, CF3+, and C2H2F3O+, to monitor it in breath. One is that CHF2+ and CF3+ also result from the reaction of O2+• with the more abundant sevoflurane. The second is the facile reaction of these product ions with water, which reduces analytical sensitivity to detect HFIP in humid breath. To overcome the first issue, C2H2F3O+ is the ion marker for HFIP. The second issue is surmounted by using a Nafion tube to reduce the breath sample's humidity prior to its introduction into drift tube. The success of this approach is illustrated by comparing the product ion signals either in dry or humid nitrogen gas flows and with or without the use of the Nafion tube, and practically from the analysis of a postoperative exhaled breath sample from a patient volunteer.
Subjects
MeSH terms (MEDLINE)
Substances
Authors and institutions
- Institute for Breath Research, Universität Innsbruck, Innrain 66, A-6020 Innsbruck, Austria.
- Department of Anaesthesiology and Critical Care, Medical University of Innsbruck, Anichstraße 35, A-6020 Innsbruck, Austria.
- Institute for Ion Physics and Applied Physics, Universität Innsbruck, Technikerstraße 25/3, A-6020 Innsbruck, Austria.
ORCID profiles: Florentin Weiss, Arne Schiller, Chris A Mayhew
Funding
- ?sterreichische Forschungsf?rderungsgesellschaft
- Universit?t Innsbruck
- Horizon 2020 Framework Programme
Cite
APA
Weiss, F., Chawaguta, A., Tolpeit, M., Volk, V., Schiller, A., Ruzsanyi, V., Hillinger, P., Lederer, W., Märk, T. D., & Mayhew, C. A. (2023). Detecting Hexafluoroisopropanol Using Soft Chemical Ionization Mass Spectrometry and Analytical Applications to Exhaled Breath. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00042
Vancouver
Weiss F, Chawaguta A, Tolpeit M, Volk V, Schiller A, Ruzsanyi V, et al. Detecting Hexafluoroisopropanol Using Soft Chemical Ionization Mass Spectrometry and Analytical Applications to Exhaled Breath. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00042
BibTeX
@article{Weiss2023,
author = {Weiss, Florentin and Chawaguta, Anesu and Tolpeit, Matthias and Volk, Valeria and Schiller, Arne and Ruzsanyi, Veronika and Hillinger, Petra and Lederer, Wolfgang and Märk, Tilmann D and Mayhew, Chris A},
title = {Detecting Hexafluoroisopropanol Using Soft Chemical Ionization Mass Spectrometry and Analytical Applications to Exhaled Breath},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2023},
doi = {10.1021/jasms.3c00042}
}
EUVIMED