EUVIMEDOpdag EUVIMED
Crossref

Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva

Justine J Demeuse iD, Chiara Calaprice, Loreen C Huyghebaert, Marwa Rechchad, Stéphanie Peeters, Etienne Cavalier, Caroline Le Goff

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.3c00021 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Justine J Demeuse and 6 co-authors. Institution: Laboratory of Clinical Chemistry, CIRM, University of Liège, 4000 Liège, Belgium. Major MEDLINE topics: Saliva, Melatonin. Cited 13 times so far (Crossref); 31 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

A growing body of literature describes the potential effects of circadian disruption on human health. Indeed, psychiatric diseases, metabolic syndrome, and cancers may be linked to disturbance of the circadian rhythm. Currently, the best practice to assess circadian rhythm is the measurement of melatonin levels. Our goal was thus to develop and validate a highly sensitive LC-MS/MS method to follow salivary melatonin levels throughout the day and night. Our method reached a lower limit of the measuring interval (LLMI) of 0.8 pg/mL. To our knowledge, it is the most sensitive method allowing quantitation of melatonin in saliva. Saliva, obtained from passive drooling or salivette, was extracted by an efficient and quick liquid-liquid extraction with no further cleanup needed. The method was validated according to the European Medicines Agency (EMA) guidelines and provided excellent results regarding accuracy, precision, linearity, selectivity, and specificity. Comparison between radioimmunoassay and our method was performed and showed differences at low levels, most likely due to cross-reactivity with other indols. To assess daytime melatonin levels in humans, salivary melatonin levels of ten volunteers were monitored throughout the day and showed lower daytime levels than reported in previous studies.

Subjects

MeSH terms (MEDLINE)

SalivaMelatoninHumansChromatography, LiquidTandem Mass SpectrometryCircadian Rhythm

Author keywords

LC-MS/MScircadian rhythmsmelatoninmethod validationultrahigh sensitivity

Substances

Melatonin

Authors and institutions

  • Laboratory of Clinical Chemistry, CIRM, University of Liège, 4000 Liège, Belgium.
  • Department of Clinical Chemistry, CHU Liège, 4000 Liège, Belgium.

ORCID profiles: Justine J Demeuse

Cite

APA

Demeuse, J. J., Calaprice, C., Huyghebaert, L. C., Rechchad, M., Peeters, S., Cavalier, E., & Le Goff, C. (2023). Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00021

Vancouver

Demeuse JJ, Calaprice C, Huyghebaert LC, Rechchad M, Peeters S, Cavalier E, et al. Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00021

BibTeX
@article{Demeuse2023,
  author = {Demeuse, Justine J and Calaprice, Chiara and Huyghebaert, Loreen C and Rechchad, Marwa and Peeters, Stéphanie and Cavalier, Etienne and Le Goff, Caroline},
  title = {Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.3c00021}
}
Start for free →