EUVIMEDEUVIMED entdecken
Crossref

Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva

Justine J Demeuse iD, Chiara Calaprice, Loreen C Huyghebaert, Marwa Rechchad, Stéphanie Peeters, Etienne Cavalier, Caroline Le Goff

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.3c00021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, 2023. Verfasst von Justine J Demeuse und 6 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Clinical Chemistry, CIRM, University of Liège, 4000 Liège, Belgium. Hauptthemen laut MEDLINE: Saliva, Melatonin. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A growing body of literature describes the potential effects of circadian disruption on human health. Indeed, psychiatric diseases, metabolic syndrome, and cancers may be linked to disturbance of the circadian rhythm. Currently, the best practice to assess circadian rhythm is the measurement of melatonin levels. Our goal was thus to develop and validate a highly sensitive LC-MS/MS method to follow salivary melatonin levels throughout the day and night. Our method reached a lower limit of the measuring interval (LLMI) of 0.8 pg/mL. To our knowledge, it is the most sensitive method allowing quantitation of melatonin in saliva. Saliva, obtained from passive drooling or salivette, was extracted by an efficient and quick liquid-liquid extraction with no further cleanup needed. The method was validated according to the European Medicines Agency (EMA) guidelines and provided excellent results regarding accuracy, precision, linearity, selectivity, and specificity. Comparison between radioimmunoassay and our method was performed and showed differences at low levels, most likely due to cross-reactivity with other indols. To assess daytime melatonin levels in humans, salivary melatonin levels of ten volunteers were monitored throughout the day and showed lower daytime levels than reported in previous studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaMelatoninHumansChromatography, LiquidTandem Mass SpectrometryCircadian Rhythm

Stichwörter der Autor:innen

LC-MS/MScircadian rhythmsmelatoninmethod validationultrahigh sensitivity

Substanzen

Melatonin

Autor:innen und Institutionen

  • Laboratory of Clinical Chemistry, CIRM, University of Liège, 4000 Liège, Belgium.
  • Department of Clinical Chemistry, CHU Liège, 4000 Liège, Belgium.

ORCID-Profile: Justine J Demeuse

Zitieren

APA

Demeuse, J. J., Calaprice, C., Huyghebaert, L. C., Rechchad, M., Peeters, S., Cavalier, E., & Le Goff, C. (2023). Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00021

Vancouver

Demeuse JJ, Calaprice C, Huyghebaert LC, Rechchad M, Peeters S, Cavalier E, et al. Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00021

BibTeX
@article{Demeuse2023,
  author = {Demeuse, Justine J and Calaprice, Chiara and Huyghebaert, Loreen C and Rechchad, Marwa and Peeters, Stéphanie and Cavalier, Etienne and Le Goff, Caroline},
  title = {Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.3c00021}
}
Kostenlos starten →