EUVIMEDDescoperă EUVIMED
Crossref

Continuous Electrospray Ionization Mass Spectrometry Assay for Measuring Phospholipase Activity against Liposomes

Julian A Harrison, Celine Kelso iD, Jennifer L Beck

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.2c00378 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Julian A Harrison and 2 co-authors. Institution: School of Chemistry and Molecular Bioscience, University of Wollongong, Wollongong, New South Wales 2522, Australia. Major MEDLINE topics: Liposomes, Spectrometry, Mass, Electrospray Ionization. Cited 2 times so far (Crossref); 41 references. Funded by: Australian Research Council.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Phospholipases have diverse roles in lipid and cell membrane biology. In animal venoms, they can have roles as neurotoxins or myotoxins that disrupt the integrity of cell membranes. In this work, we describe a temperature-controlled, continuous electrospray ionization mass spectrometry (ESI-MS) assay for measuring phospholipase A2 activity against liposomes. The enzyme used in this assay was paradoxin, which is a neurotoxic trimeric phospholipase A2 from inland taipan snake venom. Previously developed ESI-MS-based phospholipase assays have been discontinuous and analyzed hydrolysis of single lipid molecules by liquid chromatography ESI-MS. In this work, a continuous assay was developed against liposomes, a more complex substrate that more closely reflects the natural substrate for paradoxin. The assay confirmed the requirement for Ca2+ and allowed measurement of Michaelis-Menten-type parameters. The use of ESI-MS for lipid detection enabled nuanced insights into the effect of changing assay conditions not only on the enzyme but also on the liposome substrate. Changing the metal ion concentrations did not significantly change the liposomes but did affect enzymatic activity. Increasing temperature did not substantially affect the secondary structure of paradoxin but affected liposome size, resulting in increased enzymatic activity consistent with the disruption of the phosphatidylcholine membrane, increasing accessibility of sn-2 ester bonds. The continuous ESI-MS method described herein can be applied to other enzyme reactions, particularly those which utilize complex lipid substrates.

Subjects

MeSH terms (MEDLINE)

LiposomesSpectrometry, Mass, Electrospray IonizationAnimalsPhospholipases A2PhospholipasesPhosphatidylcholines

Substances

LiposomesPhospholipases A2PhospholipasesPhosphatidylcholines

Authors and institutions

  • School of Chemistry and Molecular Bioscience, University of Wollongong, Wollongong, New South Wales 2522, Australia.
  • Molecular Horizons Institute, University of Wollongong, Wollongong, New South Wales 2522, Australia.
  • Illawarra Health and Medical Research Institute, University of Wollongong, Wollongong, New South Wales 2522, Australia.

ORCID profiles: Celine Kelso

Funding

  • Australian Research Council

Cite

APA

Harrison, J. A., Kelso, C., & Beck, J. L. (2023). Continuous Electrospray Ionization Mass Spectrometry Assay for Measuring Phospholipase Activity against Liposomes. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.2c00378

Vancouver

Harrison JA, Kelso C, Beck JL. Continuous Electrospray Ionization Mass Spectrometry Assay for Measuring Phospholipase Activity against Liposomes. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.2c00378

BibTeX
@article{Harrison2023,
  author = {Harrison, Julian A and Kelso, Celine and Beck, Jennifer L},
  title = {Continuous Electrospray Ionization Mass Spectrometry Assay for Measuring Phospholipase Activity against Liposomes},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.2c00378}
}
Start for free →