EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

Ultra-Accurate Correlation between Precursor and Fragment Ions in Two-Dimensional Mass Spectrometry: Acetylated vs Trimethylated Histone Peptides

Michael Palasser, Sarah V Heel, Marc-André Delsuc iD, Kathrin Breuker, Maria A van Agthoven iD

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.2c00319 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Michael Palasser and 4 co-authors. Institution: Institute for Organic Chemistry, University of Innsbruck, 80/82 Innrain, 6020 Innsbruck, Austria. Major MEDLINE topics: Histones, Peptides. Cited 3 times so far (Crossref); 53 references. The full text is freely available (open access, CC BY 4.0). Funded by: Austrian Science Fund.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Two-dimensional mass spectrometry (2D MS) is a method for tandem mass spectrometry in which precursor and fragment ions are correlated by manipulating ion radii rather than by ion isolation. A 2D mass spectrum contains the fragmentation patterns of all analytes in a sample, acquired in parallel. We report ultrahigh-resolution narrowband 2D mass spectra of a mixture of two histone peptides with the same sequence, one of which carries an acetylation and the other a trimethylation (m/z 0.006 difference). We reduced the distance between data points in the precursor ion dimension and compared the accuracy of the precursor-fragment correlation with the resolving power. We manage to perform label-free quantification on the histone peptide mixture and show that precursor and fragment ions can be accurately correlated even though the precursor ions are not resolved. Finally, we show that increasing the resolution of a 2D mass spectrum in the precursor ion dimension too far can lead to a decline in the signal-to-noise ratio.

Subjects

MeSH terms (MEDLINE)

HistonesPeptidesTandem Mass SpectrometryProtein Processing, Post-TranslationalIons

Substances

HistonesPeptidesIons

Authors and institutions

  • Institute for Organic Chemistry, University of Innsbruck, 80/82 Innrain, 6020 Innsbruck, Austria.
  • Institut de Génétique et de Biologie Moléculaire et Cellulaire, INSERM U596, UMR 7104, Université de Strasbourg, 1 rue Laurent Fries, 67404 Illkirch-Graffenstaden, France.
  • CASC4DE, Pôle API, 300 Bd. Sébastien Grant, 67400 Illkirch-Graffenstaden, France.

ORCID profiles: Marc-André Delsuc, Maria A van Agthoven

Funding

  • Austrian Science Fund

Cite

APA

Palasser, M., Heel, S. V., Delsuc, M. A., Breuker, K., & van Agthoven, M. A. (2023). Ultra-Accurate Correlation between Precursor and Fragment Ions in Two-Dimensional Mass Spectrometry: Acetylated vs Trimethylated Histone Peptides. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.2c00319

Vancouver

Palasser M, Heel SV, Delsuc MA, Breuker K, van Agthoven MA. Ultra-Accurate Correlation between Precursor and Fragment Ions in Two-Dimensional Mass Spectrometry: Acetylated vs Trimethylated Histone Peptides. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.2c00319

BibTeX
@article{Palasser2023,
  author = {Palasser, Michael and Heel, Sarah V and Delsuc, Marc-André and Breuker, Kathrin and van Agthoven, Maria A},
  title = {Ultra-Accurate Correlation between Precursor and Fragment Ions in Two-Dimensional Mass Spectrometry: Acetylated vs Trimethylated Histone Peptides},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.2c00319}
}
Start for free →