Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection
ACS Sensors · 12.11.2026
DOI: 10.1021/acssensors.6c03378 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 12.11.2026. Verfasst von Zitao Wang und 11 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Laboratory for Next Generation Internet Access System, School of Optical and Electronic Information, Huazhong University of Scie…. Die Arbeit nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Huazhong University of Science and Technology, Wuhan Union Hospital.
Abstract (Originalsprache)
Esophageal squamous cell carcinoma (ESCC) is one of the most aggressive malignancies of the digestive tract, making early detection critically important for improving patient survival and treatment outcomes. Biomarker detection is routinely employed as one of the primary modalities for the identification of ESCC. Despite advantages of high sensitivity and fast response, current optical fiber biosensors still face the main challenges of multi-biomarker detection to reduce false-positive results and compensation of the interference from bulk refractive index (BRI) variations for reliable measurement. Here, we report a distributed fiber-optic biosensor capable of simultaneously detecting ESCC dual biomarkers with BRI self-compensation. A step-tapered fiber (STF) sensor is designed with two distinct tapered regions for biomarker detection with BRI compensation. Optical frequency domain reflectometry is employed to simultaneously interrogate the two regions, enabling accurate and rapid detection of ESCC dual biomarkers in a single-shot distributed measurement. Simultaneous detection of both Cyfra21-1 and squamous cell carcinoma antigen (SCCA) biomarkers has been demonstrated within a short assay time of less than 30 min and with an average relative error of 13.8 and 15%, respectively, showing 4.5 times and 11.5 times accuracy improvement when compared to those without BRI compensation. Limits of detection of 0.07 and 0.1 ng/mL have been achieved for Cyfra21-1 and SCCA detection, respectively. The capability of multi-biomarker detection with BRI self-compensation would greatly reduce false-positive rates in ESCC diagnosis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Engineering Laboratory for Next Generation Internet Access System, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan430074, China.
- Department of Thoracic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan430030, China.
- Division of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan430022, China.
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan430022, China.
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan430074, China.
ORCID-Profile: Liang Wang
Förderung
- National Natural Science Foundation of China
- Huazhong University of Science and Technology
- Wuhan Union Hospital
- Key Research and development Program of Hubei Province
Zitieren
APA
Wang, Z., Ping, W., Tu, L., Chen, T., Xu, Z., Wu, Y., Ji, Z., Lu, Z., Kan, X., Yan, L., Wang, L., & Tang, M. (2026). Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection. ACS Sensors. https://doi.org/10.1021/acssensors.6c03378
Vancouver
Wang Z, Ping W, Tu L, Chen T, Xu Z, Wu Y, et al. Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection. ACS Sensors. 2026. doi:10.1021/acssensors.6c03378
BibTeX
@article{Wang2026,
author = {Wang, Zitao and Ping, Wei and Tu, Lei and Chen, Tianle and Xu, Zhou and Wu, Yikai and Ji, Zihang and Lu, Zhenjie and Kan, Xuefeng and Yan, Lisong and Wang, Liang and Tang, Ming},
title = {Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c03378}
}
EUVIMED