Immunosensor Based on Gold Nanoparticles Encapsulated in Azo-Polymer and Reduced Graphene Oxide for the Detection of the Proinflammatory Molecule Interleukin-6
ACS Sensors · 2026
DOI: 10.1021/acssensors.6c01351 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Gabriel M Silva und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, School of Science and Technology, Sao Paulo State University (UNESP), Rua Roberto Simonsen 305, Presidente …. Hauptthemen laut MEDLINE: Graphite, Gold, Interleukin-6, Metal Nanoparticles. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Rapid interleukin-6 (IL-6) monitoring is essential for the early diagnosis and management of inflammatory and oncological conditions. This study reports a label-free impedimetric immunosensor based on a ternary poly(azo-BBY)-AuNP/rGO nanocomposite synthesized via a single-step electrochemical process. The platform utilizes dissolved oxygen as an intrinsic redox probe, precluding the need for external mediators. Morphological characterization confirmed a synergistic architecture where gold nanoparticles are encapsulated within the polymeric matrix and covered by a reduced graphene oxide veil, reducing charge-transfer resistance by over 90%. The immunosensor achieved a detection limit of 2.51 pg mL–1 with a linear range between 5 and 30 pg mL–1. A thermodynamic investigation via the Freundlich isotherm revealed a dual-stage adsorption mechanism and a steric “gate effect”. Selectivity assays demonstrated high specificity, including the competitive displacement of IL-6 by the IL-1 receptor antagonist (IL-1RA). Practical utility was validated in cell culture, yielding results statistically equivalent to the ELISA gold standard. Operational stability was established for 4 days within a 95% confidence interval (97.2%–115.1%). These findings support the proposed platform as a proof-of-concept label-free immunosensor for IL-6 monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, School of Science and Technology, Sao Paulo State University (UNESP), Rua Roberto Simonsen 305, Presidente Prudente, São Paulo19060-900, Brazil.
- Department of Physical Education, School of Science and Technology, Sao Paulo State University (UNESP), Presidente Prudente, São Paulo19060-900, Brazil.
ORCID-Profile: Gabriel M Silva, Pedro C M Pizzol, Marcos F S Teixeira
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
Zitieren
APA
Silva, G. M., Pizzol, P. C. M., S Lira, F., & Teixeira, M. F. S. (2026). Immunosensor Based on Gold Nanoparticles Encapsulated in Azo-Polymer and Reduced Graphene Oxide for the Detection of the Proinflammatory Molecule Interleukin-6. ACS Sensors. https://doi.org/10.1021/acssensors.6c01351
Vancouver
Silva GM, Pizzol PCM, S Lira F, Teixeira MFS. Immunosensor Based on Gold Nanoparticles Encapsulated in Azo-Polymer and Reduced Graphene Oxide for the Detection of the Proinflammatory Molecule Interleukin-6. ACS Sensors. 2026. doi:10.1021/acssensors.6c01351
BibTeX
@article{Silva2026,
author = {Silva, Gabriel M and Pizzol, Pedro C M and S Lira, Fábio and Teixeira, Marcos F S},
title = {Immunosensor Based on Gold Nanoparticles Encapsulated in Azo-Polymer and Reduced Graphene Oxide for the Detection of the Proinflammatory Molecule Interleukin-6},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c01351}
}
EUVIMED