EUVIMEDEUVIMED entdecken
Crossref

Robust and Sensitive Electrochemical Biosensor Based on Cascade Interface Engineering for piRNA Detection in Breast Cancer Diagnosis

Xinyu Zhang, Rubing Xiong, Zijie Li, Zhiqi Li, Chenfei Liu, Yongmei Chen, Zhengkun Liu, Huanyu Zhou, Yong Xia, Honghai Hong, Lei Mou iD

ACS Sensors · 24.07.2026 · 11 (7) · 5942-5953

DOI: 10.1021/acssensors.6c00790 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 01.07.2026. Verfasst von Xinyu Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Guangdong Provincial Key Laboratory of Major Obstetric Diseases, Guangdong Provincial Clinical Research Center for…. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, Breast Neoplasms, RNA, Small Interfering. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Guangzhou Medical University, Guangdong Provincial Department of Science and Technology, Guangzhou Municipal Science and Technology Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Point-of-care electrochemical sensors require interfaces that simultaneously deliver high sensitivity, mechanical robustness, and long-term stability. These requirements remain difficult to reconcile at nanostructured electrode interfaces. Here, we report a cascade interfacial engineering strategy that integrates plasma-synthesized polydopamine (PDA), MXene nanosheets, and gold nanoparticles (AuNPs) to construct a high-performance electrochemical sensing interface. A rapid, one-minute plasma process forms a conductive PDA interlayer that serves both as a universal adhesive and as a mediator for the in situ electrodeposition of MXene and pH-regulated AuNPs, yielding a mechanically resilient and highly conductive nanocomposite electrode. This architecture markedly enhances electroactive surface area, electron transport, and interfacial stability under repeated mechanical deformation and prolonged storage. When coupled with catalytic hairpin assembly, the resulting platform enables ultrasensitive nucleic acid detection down to the femtomolar regime (within the linear range of 0–100 nM, the limits of detection are 0.14, 0.44, and 0.06 fM, respectively) and maintains high reproducibility across batches (RSD as low as 2.05%). Integration with a portable printed circuit board further enables reliable analysis of clinical serum samples. Beyond a specific biosensing application, this work establishes a generalizable interface-engineering paradigm for stabilizing nanomaterial-modified electrodes, advancing the design of robust, scalable point-of-care electrochemical systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrochemical TechniquesBreast NeoplasmsRNA, Small InterferingGoldMetal NanoparticlesHumansLimit of DetectionElectrodesPolymersIndoles

Stichwörter der Autor:innen

PDA-MXene-AuNPsPOCTelectrochemical biosensorelectrochemical depositionpiRNA detection

Substanzen

GoldRNA, Small InterferingPolymerspolydopamineIndoles

Autor:innen und Institutionen

  • Department of Clinical Laboratory, Guangdong Provincial Key Laboratory of Major Obstetric Diseases, Guangdong Provincial Clinical Research Center for Obstetrics and Gynecology, The Third Affiliated Hospital, Guangzhou M…
  • The Key Laboratory of Advanced Interdisciplinary Studies, The First Affiliated Hospital of Guangzhou Medical University, School of Biomedical Engineering, Guangzhou Medical University, Yanjiang Road, Yuexiu District, Gu…

ORCID-Profile: Lei Mou

Förderung

  • Guangzhou Medical University
  • Guangdong Provincial Department of Science and Technology
  • Guangzhou Municipal Science and Technology Project
  • Guangzhou Municipal Health and Family Planning Commission
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Zhang, X., Xiong, R., Li, Z., Li, Z., Liu, C., Chen, Y., Liu, Z., Zhou, H., Xia, Y., Hong, H., & Mou, L. (2026). Robust and Sensitive Electrochemical Biosensor Based on Cascade Interface Engineering for piRNA Detection in Breast Cancer Diagnosis. ACS Sensors, 11(7), 5942-5953. https://doi.org/10.1021/acssensors.6c00790

Vancouver

Zhang X, Xiong R, Li Z, Li Z, Liu C, Chen Y, et al. Robust and Sensitive Electrochemical Biosensor Based on Cascade Interface Engineering for piRNA Detection in Breast Cancer Diagnosis. ACS Sensors. 2026;11(7):5942-5953. doi:10.1021/acssensors.6c00790

BibTeX
@article{Zhang2026,
  author = {Zhang, Xinyu and Xiong, Rubing and Li, Zijie and Li, Zhiqi and Liu, Chenfei and Chen, Yongmei and Liu, Zhengkun and Zhou, Huanyu and Xia, Yong and Hong, Honghai and Mou, Lei},
  title = {Robust and Sensitive Electrochemical Biosensor Based on Cascade Interface Engineering for piRNA Detection in Breast Cancer Diagnosis},
  journal = {ACS Sensors},
  year = {2026},
  volume = {11},
  number = {7},
  pages = {5942--5953},
  doi = {10.1021/acssensors.6c00790}
}
Kostenlos starten →