Electrochemical Immunosensor Based on CS@AuNPs/ZIF-8/rGO Composite for Detecting CA15-3 in Human Serum
Sensors · 2025
DOI: 10.3390/s25247462 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Yuanyue Lu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Department of Medical Sciences, Wuhan University of Science and Tech…. Hauptthemen laut MEDLINE: Metal Nanoparticles, Electrochemical Techniques, Biosensing Techniques, Mucin-1. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
An electrochemical immunosensor was fabricated to identify CA15-3, a biomarker for breast cancer (BC). A composite sensor substrate made of “zeolitic imidazolate framework-8” (ZIF-8) and “reduced graphene oxide” (rGO) was chosen and its conductivity was further improved by the addition of chitosan (CS)-doped gold nanoparticles (AuNPs). The CS@AuNPs are able to conjugate with antibodies via the strong Au-S interaction, which offers multiple active sites for antibody immobilization and enhances the sensor performance. This immunosensor is capable of ultrasensitive detection of CA15-3 by specific antigen–antibody –interactions. In healthy people, normal serum CA15-3 is up to 25 U/mL. Under optimized experimental conditions, the alteration in the signal intensity measured by the sensor was related to the CA15-3 activity. The quantitative relationship was linear over 0.001–400 U/mL with a limit of detection (LOD) of 0.0031 U/mL at a “signal-to-noise ratio” (S/N) of 3 and a “correlation coefficient” (r2) of 0.9983. The developed immunosensor showed great accuracy, stability, and selectivity, and was able to detect CA15-3 in human serum samples. These results validate its potential as a reliable analytical platform for BC diagnosis and early clinical screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Department of Medical Sciences, Wuhan University of Science and Technology, Wuhan 430000, China.
Zitieren
APA
Lu, Y., Mei, Y., Gu, Y., Tao, Y., Yang, Y., Yu, J., Zhang, Y., Liu, L., & Li, X. (2025). Electrochemical Immunosensor Based on CS@AuNPs/ZIF-8/rGO Composite for Detecting CA15-3 in Human Serum. Sensors. https://doi.org/10.3390/s25247462
Vancouver
Lu Y, Mei Y, Gu Y, Tao Y, Yang Y, Yu J, et al. Electrochemical Immunosensor Based on CS@AuNPs/ZIF-8/rGO Composite for Detecting CA15-3 in Human Serum. Sensors. 2025. doi:10.3390/s25247462
BibTeX
@article{Lu2025,
author = {Lu, Yuanyue and Mei, Yong and Gu, Yingying and Tao, Ye and Yang, Yuhan and Yu, Jiao and Zhang, Yang and Liu, Lin and Li, Xin},
title = {Electrochemical Immunosensor Based on CS@AuNPs/ZIF-8/rGO Composite for Detecting CA15-3 in Human Serum},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25247462}
}
EUVIMED