Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration
ACS Sensors · 28.11.2025 · 10 (11) · 8917-8924
DOI: 10.1021/acssensors.5c02930 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 10.11.2025. Verfasst von Seonhwa Park und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Electrochemical immunosensors offer rapid, sensitive biomarker detection but typically rely on complex three- or two-electrode architectures with dedicated reference electrodes, complicating fabrication and miniaturization. Herein, we present an electrochemical immunosensor based on a diffusion-isolated, two-electrode system of micropatterned indium tin oxide (ITO) that eliminates the need for a separate reference electrode. A kinetically robust (fast, surface-insensitive) redox mediator [Os(bpy)2Cl2+/Os(bpy)2Cl2 (OsIII/OsII)] simultaneously acts as the enzymatic substrate, the counterbalancing electroactive species, and the potential-guiding element, removing the requirement for additional electroactive species. Further, diaphorase (DI) is employed as the catalytic label in a sandwich-type immunosensor for prostate-specific antigen (PSA), rapidly reducing OsIII to OsII in the presence of reduced nicotinamide adenine dinucleotide (NADH), enabling efficient electrochemical-enzymatic redox cycling involving the ITO electrode, OsIII, DI, and NADH. By patterning the working and auxiliary electrodes 1.0 mm apart, we achieved diffusion isolation that prevents cross-talk between electrodes. After optimizing blocking, potential difference, and incubation conditions, the sensor achieved a detection limit of approximately 20 pg/mL and a detection range of 20-10 ng/mL in spiked human serum. The results of our analysis of clinical serum samples correlated closely with those of a commercial PSA assay, demonstrating both analytical accuracy and robustness. This study establishes a streamlined, point-of-care-compatible platform that achieves stable potential control and robust kinetics without a dedicated reference electrode.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea.
ORCID-Profile: Youngsuk Kim, Haesik Yang
Förderung
- National Research Foundation of Korea
Zitieren
APA
Park, S., Kim, J., Park, S., Kim, Y., & Yang, H. (2025). Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration. ACS Sensors, 10(11), 8917-8924. https://doi.org/10.1021/acssensors.5c02930
Vancouver
Park S, Kim J, Park S, Kim Y, Yang H. Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration. ACS Sensors. 2025;10(11):8917-8924. doi:10.1021/acssensors.5c02930
BibTeX
@article{Park2025,
author = {Park, Seonhwa and Kim, Jihyeon and Park, Subin and Kim, Youngsuk and Yang, Haesik},
title = {Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration},
journal = {ACS Sensors},
year = {2025},
volume = {10},
number = {11},
pages = {8917--8924},
doi = {10.1021/acssensors.5c02930}
}
EUVIMED