A Low‐Fouling Electrochemical Immunosensor Based On Metal–Organic Framework and Ternary Metal Oxide Nanomaterials Using Dual Signal Amplification Strategy for Sensitive Detection of Prostate‐Specific Antigen (PSA) in Patient Samples
Biotechnology and Applied Biochemistry · 2025
DOI: 10.1002/bab.2752 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology and Applied Biochemistry, 2025. Verfasst von Abdulsalam Y Obaid und 10 weiteren Autor:innen. Beteiligte Einrichtung: Engineering Affairs, University of Fallujah, Fallujah, Iraq. Hauptthemen laut MEDLINE: Prostate-Specific Antigen, Metal-Organic Frameworks, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Prince Sattam bin Abdulaziz University.
Abstract (Originalsprache)
A label‐free electrochemical immunosensor based on the zeolitic imidazolate framework‐8 (ZIF8)/bismuth ferrite (BFO) nanocomposite was fabricated for the specific and sensitive quantification of prostate‐specific antigen (PSA). The ZIF8‐BFO material not only increases the surface area effectively but also enhances the catalytic capability of the electrode through a dual amplification strategy, leading to the improved sensitivity of the probe for PSA recognition. A thin layer of l ‐cysteine was used for two reasons: providing a scaffold for the next functionalization and reducing the fouling of plasma ingredients on the surface of the probe. The mechanical and spectroscopic properties of the produced nanomaterials were characterized using different techniques such as field emission scanning electron microscopy (FESEM), x‐ray diffraction (XRD), atomic force microscopy (AFM), the Fourier transform infrared (FTIR), and dynamic light scattering (DLS)/Zeta analyzer. The electroanalytical properties of the probe were studied using square‐wave voltammetry (SWV) and cyclic voltammetry (CV). The signal of the probe decreased proportionally with increasing PSA concentration in the 100.0 pg/mL–15.0 ng/mL range, with a limit of detection (LOD) of 85 pg/mL. The proposed platform has been successfully employed to measure PSA levels in human serum samples with acceptable accuracy. The capability of the probe was evaluated in detecting PSA in patient's serum samples, with results compared to those obtained from the gold standard enzyme‐linked immunosorbent assay (ELISA). The results suggested that the ZIF8‐BFO material‐based probe could be used as a promising method for detecting PSA and tracing therapy progression in clinics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Engineering Affairs, University of Fallujah, Fallujah, Iraq.
- Department of Medical Laboratory Techniques, College of Health and Medical Techniques, University of Alkafeel, Najaf, Iraq.
- Department of Medical Laboratory Sciences, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia.
- Faculty of Chemical Engineering, New Uzbekistan University, Tashkent, Uzbekistan.
- Scientific and Innovation Department, Tashkent State Pedagogical University, Tashkent, Uzbekistan.
- Medical Laboratory Sciences Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia.
ORCID-Profile: Abdulsalam Y Obaid, Mosleh Mohammad Abomughaid
Förderung
- Prince Sattam bin Abdulaziz University
Zitieren
APA
Obaid, A. Y., Alaridhee, Z. A. I., Hjazi, A., Juraev, N., Maashi, M. S., Zankanah, F. H., Al-Rubaye, A. H., Hussam, A. S., Abomughaid, M. M., Majdi, H., & Jabir, M. (2025). A Low‐Fouling Electrochemical Immunosensor Based On Metal–Organic Framework and Ternary Metal Oxide Nanomaterials Using Dual Signal Amplification Strategy for Sensitive Detection of Prostate‐Specific Antigen (PSA) in Patient Samples. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.2752
Vancouver
Obaid AY, Alaridhee ZAI, Hjazi A, Juraev N, Maashi MS, Zankanah FH, et al. A Low‐Fouling Electrochemical Immunosensor Based On Metal–Organic Framework and Ternary Metal Oxide Nanomaterials Using Dual Signal Amplification Strategy for Sensitive Detection of Prostate‐Specific Antigen (PSA) in Patient Samples. Biotechnology and Applied Biochemistry. 2025. doi:10.1002/bab.2752
BibTeX
@article{Obaid2025,
author = {Obaid, Abdulsalam Y and Alaridhee, Zaman Abdalhussein Ibadi and Hjazi, Ahmed and Juraev, Nizomiddin and Maashi, Marwah Suliman and Zankanah, Faeza H and Al-Rubaye, Ameer H and Hussam, Albe Slabi and Abomughaid, Mosleh Mohammad and Majdi, Hasan and Jabir, Majid},
title = {A Low‐Fouling Electrochemical Immunosensor Based On Metal–Organic Framework and Ternary Metal Oxide Nanomaterials Using Dual Signal Amplification Strategy for Sensitive Detection of Prostate‐Specific Antigen (PSA) in Patient Samples},
journal = {Biotechnology and Applied Biochemistry},
year = {2025},
doi = {10.1002/bab.2752}
}
EUVIMED