EUVIMEDEUVIMED entdecken
Crossref

Effect of Electrode Structure on Glucose Monitoring by Reverse Iontophoresis

Hao Zheng, Youhao Liu, Wenjun Li, Xingguo Zhang iD, Wangwang Zhu, Jialing Wang, Yuxuan Chen, Dachao Li iD, Zhihua Pu iD, Fei Xie iD

ACS Sensors · 24.10.2025 · 10 (10) · 7947-7958

DOI: 10.1021/acssensors.5c02487 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 20.09.2025. Verfasst von Hao Zheng und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China. Hauptthemen laut MEDLINE: Iontophoresis, Blood Glucose Self-Monitoring, Blood Glucose, Glucose. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Key Research and Development Program of China, China Postdoctoral Science Foundation, Young Scientific and Technological Talents in Tianjin.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous glucose monitoring (CGM) based on reverse iontophoresis (RI) offers a promising noninvasive solution for diabetes management. However, in the application of this technology, there are two key issues that affect the glucose detection results: the sensor sensitivity is gradually reduced due to the influence of the extraction current; the insufficient glucose extraction flux affects the accuracy of glucose prediction. We found that the electrode structure has a regulatory effect on these two types of influences. However, to date, there was no comprehensive or systematic investigation into the role of electrode structure in influencing the efficiency and accuracy of reverse iontophoresis-based glucose monitoring. This study investigated the impact of electrode structure on RI through multiphysics simulation, in vitro experiments, and human trials. By optimizing the spatial arrangement, spacing, shape, and position of the electrodes, the sensor sensitivity decline was minimized and the glucose extraction flux was maximized. Human trials verified the optimized design, achieving 74% of data points within the clinically accurate Clarke error grid A zone, with a mean absolute relative difference (MARD) of 13.17%, compared to 62 and 21.06% for the previous structure. These findings highlight the crucial role of electrode geometry in enhancing the accuracy of RI-based CGM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IontophoresisBlood Glucose Self-MonitoringBlood GlucoseGlucoseHumansElectrodes

Stichwörter der Autor:innen

electrode structureflexible electrodeglucose sensornoninvasive glucose monitoringreverse iontophoresis

Substanzen

Blood GlucoseGlucose

Autor:innen und Institutionen

  • State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China.
  • College of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing 100853, China.

ORCID-Profile: Xingguo Zhang, Dachao Li, Zhihua Pu, Fei Xie

Förderung

  • National Key Research and Development Program of China
  • China Postdoctoral Science Foundation
  • Young Scientific and Technological Talents in Tianjin

Zitieren

APA

Zheng, H., Liu, Y., Li, W., Zhang, X., Zhu, W., Wang, J., Chen, Y., Li, D., Pu, Z., & Xie, F. (2025). Effect of Electrode Structure on Glucose Monitoring by Reverse Iontophoresis. ACS Sensors, 10(10), 7947-7958. https://doi.org/10.1021/acssensors.5c02487

Vancouver

Zheng H, Liu Y, Li W, Zhang X, Zhu W, Wang J, et al. Effect of Electrode Structure on Glucose Monitoring by Reverse Iontophoresis. ACS Sensors. 2025;10(10):7947-7958. doi:10.1021/acssensors.5c02487

BibTeX
@article{Zheng2025,
  author = {Zheng, Hao and Liu, Youhao and Li, Wenjun and Zhang, Xingguo and Zhu, Wangwang and Wang, Jialing and Chen, Yuxuan and Li, Dachao and Pu, Zhihua and Xie, Fei},
  title = {Effect of Electrode Structure on Glucose Monitoring by Reverse Iontophoresis},
  journal = {ACS Sensors},
  year = {2025},
  volume = {10},
  number = {10},
  pages = {7947--7958},
  doi = {10.1021/acssensors.5c02487}
}