Linear Ligand-Regulated Coordination Aggregation-Induced Electrochemiluminescence for Circulating Tumor DNA Measurement Combined with a Cruciform Tripedal DNA Walker Output Strategy
ACS Sensors · 24.10.2025 · 10 (10) · 7832-7841
DOI: 10.1021/acssensors.5c02240 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 09.10.2025. Verfasst von Yu Hu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engine…. Hauptthemen laut MEDLINE: Electrochemical Techniques, Luminescent Measurements, Biosensing Techniques, Circulating Tumor DNA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Natural Science Foundation Project of Chongqing, Chongqing Science and Technology Commission, National Natural Science Foundation of China.
Abstract (Originalsprache)
The regulation of the aggregation degree plays a crucial role in the aggregation-induced electrochemiluminescence (AIECL) induced by coordination aggregation. Herein, 1,3,5-tri(4-carboxyphenyl) benzene (H3BTB), 1,4-di(pyridin-4-yl) benzene (DPB), and Zn2+ were first employed to synthesize the Zn-DPB-BTB coordination polymers (Zn-DPB-BTB CPs) with extraordinary AIECL performance as the rotation and vibration of luminescent H3BTB were restricted. Notably, besides the coordination-induced ECL enhancement, DPB, a functional linear molecule, could effectively adjust the parallel π-π stacking pattern and the aggregation degree of Zn-BTB, enabling Zn-DPB-BTB CPs to possess significantly improved ECL efficiency at low voltage compared to H3BTB and Zn-BTB. Hence, using Zn-DPB-BTB CPs as efficient ECL emitters, an ECL biosensor for ultrasensitive detection of circulating tumor DNA was fabricated combined with a newly designed target cleavage-induced cruciform tripedal DNA walker output strategy. Specifically, it exhibited obvious advantages in sensitive and accurate analysis of low-concentration targets as multiple sufficient preformed cruciform tripedal DNA walkers on the three-dimensional surface of magnetic beads were released for more effective signal conversion via target cleavage compared with the traditional DNA walker that was directly triggered and formed through targets. Impressively, the proposed biosensor revealed a good linear range of 10 aM to 1 nM and an excellent detection limit as low as 8.24 aM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P.R. China.
ORCID-Profile: Ruo Yuan, Hai-Jun Wang
Förderung
- Natural Science Foundation Project of Chongqing, Chongqing Science and Technology Commission
- National Natural Science Foundation of China
Zitieren
APA
Hu, Y., Wang, Z., Chen, Y. F., Yang, J. L., Wang, L., Yuan, R., & Wang, H. J. (2025). Linear Ligand-Regulated Coordination Aggregation-Induced Electrochemiluminescence for Circulating Tumor DNA Measurement Combined with a Cruciform Tripedal DNA Walker Output Strategy. ACS Sensors, 10(10), 7832-7841. https://doi.org/10.1021/acssensors.5c02240
Vancouver
Hu Y, Wang Z, Chen YF, Yang JL, Wang L, Yuan R, et al. Linear Ligand-Regulated Coordination Aggregation-Induced Electrochemiluminescence for Circulating Tumor DNA Measurement Combined with a Cruciform Tripedal DNA Walker Output Strategy. ACS Sensors. 2025;10(10):7832-7841. doi:10.1021/acssensors.5c02240
BibTeX
@article{Hu2025,
author = {Hu, Yu and Wang, Zhen and Chen, Yi-Fei and Yang, Jin-Li and Wang, Li and Yuan, Ruo and Wang, Hai-Jun},
title = {Linear Ligand-Regulated Coordination Aggregation-Induced Electrochemiluminescence for Circulating Tumor DNA Measurement Combined with a Cruciform Tripedal DNA Walker Output Strategy},
journal = {ACS Sensors},
year = {2025},
volume = {10},
number = {10},
pages = {7832--7841},
doi = {10.1021/acssensors.5c02240}
}
EUVIMED