EUVIMEDEUVIMED entdecken
Crossref

Intramolecular Electrochemiluminescence Resonant Energy Transfer Biosensor Utilizing Ir-Grafted 2D Hf-MOL and Circular DNA Walker for Ultrasensitive Detection of microRNA-21 in Non-Small-Cell Lung Cancer Diagnostics

Binnan Shi, Luyang Lv, Dehao Jia, Zhuangzhuang Ru, Shuyuan Liu, Yu Du iD, Jingshuai Li, Qin Wei iD

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.5c02322 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Binnan Shi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Ji…. Hauptthemen laut MEDLINE: MicroRNAs, Carcinoma, Non-Small-Cell Lung, Biosensing Techniques, Lung Neoplasms. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Yunnan Provincial Science and Technology Plan Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid advancement in non-small-cell lung cancer (NSCLC) diagnostics demands ultrasensitive biosensors for detecting microRNA-21 (miRNA-21), a pivotal prognostic biomarker. An innovative electrochemiluminescence (ECL) biosensor was developed that leverages ECL resonance energy transfer (ECL-RET) as the primary amplification mechanism for ultrasensitive detection. The biosensor integrated a two-dimensional hafnium-based metal-organic layer (Hf-MOL) functionalized with iridium complexes (Ir-Hf-MOL), which serves as an efficient ECL emitter. Enhanced sensitivity is achieved through precise spectral overlap and Förster radius optimization, enabling stable energy transfer from Hf-MOL to Ir-COOH. The structural rigidity of Ir-Hf-MOL further contributed to suppressing nonradiative decay through restricted molecular motion. Charge transfer feasibility is validated via density functional theory (DFT), while a circular DNA walker-mediated amplification strategy is incorporated to augment specificity and signal amplification. The optimized system achieves an exceptional linear range from 1 aM to 1 nM, with a low detection limit of 0.76 aM. Rigorous evaluations of selectivity, stability, and recovery rates (99.4-103.2%) in human serum and Bland-Altman plots confirm clinical applicability. This work establishes a transformative biosensing platform for miRNA-21 detection, emphasizing ECL-RET-driven innovation, and advances diagnostic strategies for NSCLC.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsCarcinoma, Non-Small-Cell LungBiosensing TechniquesLung NeoplasmsElectrochemical TechniquesIridiumMetal-Organic FrameworksHumansLuminescent MeasurementsLimit of DetectionEnergy TransferCoordination Complexes

Substanzen

MicroRNAsMIRN21 microRNA, humanIridiumMetal-Organic FrameworksCoordination Complexes

Autor:innen und Institutionen

  • Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, Shandong, China.
  • College of Pharmacy, Dali University, Dali 671000, Yunnan, China.
  • School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China.
  • Department of Chemistry, Sungkyunkwan University, Suwon 16419, Republic of Korea.

ORCID-Profile: Yu Du, Qin Wei

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province
  • Yunnan Provincial Science and Technology Plan Project

Zitieren

APA

Shi, B., Lv, L., Jia, D., Ru, Z., Liu, S., Du, Y., Li, J., & Wei, Q. (2025). Intramolecular Electrochemiluminescence Resonant Energy Transfer Biosensor Utilizing Ir-Grafted 2D Hf-MOL and Circular DNA Walker for Ultrasensitive Detection of microRNA-21 in Non-Small-Cell Lung Cancer Diagnostics. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c02322

Vancouver

Shi B, Lv L, Jia D, Ru Z, Liu S, Du Y, et al. Intramolecular Electrochemiluminescence Resonant Energy Transfer Biosensor Utilizing Ir-Grafted 2D Hf-MOL and Circular DNA Walker for Ultrasensitive Detection of microRNA-21 in Non-Small-Cell Lung Cancer Diagnostics. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c02322

BibTeX
@article{Shi2025,
  author = {Shi, Binnan and Lv, Luyang and Jia, Dehao and Ru, Zhuangzhuang and Liu, Shuyuan and Du, Yu and Li, Jingshuai and Wei, Qin},
  title = {Intramolecular Electrochemiluminescence Resonant Energy Transfer Biosensor Utilizing Ir-Grafted 2D Hf-MOL and Circular DNA Walker for Ultrasensitive Detection of microRNA-21 in Non-Small-Cell Lung Cancer Diagnostics},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.5c02322}
}
Kostenlos starten →