Spectrally Silent and Optically Transparent: Clear-SiR for Deep Raman Biomolecular Sensing
ACS Sensors · 2025
DOI: 10.1021/acssensors.5c02046 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2025. Verfasst von Michael Ka Ho Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, Japan Science and Technology Agency, National Institute of General Medical Sciences.
Abstract (Originalsprache)
Raman spectroscopy (RS) offers highly specific, label-free molecular identification, yet its application in deep-tissue imaging is fundamentally limited by light scattering and spectral interference from endogenous biomolecules. A promising strategy to mitigate these issues involves using vibrational tags that emit signals within the Raman-silent region (1800-2800 cm-1), minimizing background noise. However, these signals remain susceptible to attenuation due to the inherent optical opacity of biological tissues caused by refractive index (RI) mismatches among tissue constituents. Here, we introduce Clearing-enabled Light Enhancement for Analytical Raman in the Silent Region (Clear-SiR), a hybrid method that combines RI modulation through tissue clearing with spectral targeting in the silent region to enable high-fidelity Raman detection through biological tissue. Utilizing tartrazine, an FDA-approved dye with strong short-wavelength absorption, Clear-SiR homogenizes tissue RI based on the Kramers-Kronig relations, enhancing optical transparency and reducing light scattering. Paired with 4-aminobenzonitrile (4-ABN) as a nitrile-based silent region reporter, we demonstrate that Clear-SiR achieves up to a nearly 2-fold increase in detection depth under red (638 nm) and near-infrared (785 nm) excitation. We further use a rapid, gel-based tartrazine delivery protocol suitable for clinical and point-of-care settings. Our proof-of-concept results demonstrate that Clear-SiR overcomes both spectral and optical barriers for transcutaneous measurement, enabling highly accurate, deep-tissue biochemical sensing with minimal distraction from endogenous signals. By integration of physical tissue clearing with spectral targeting in the Raman-silent region, this method establishes a robust platform for probing molecular architecture at clinically relevant depths. Clear-SiR opens new avenues for noninvasive molecular phenotyping and longitudinal monitoring of pathophysiological process in organoids and intact tissues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States.
- Department of Applied Physics, Osaka University, Suita, Osaka 565-0871, Japan.
- Institute for Open and Transdisciplinary Research Initiatives, Osaka University, Suita, Osaka 565-0871, Japan.
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, United States.
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, United States.
ORCID-Profile: Peng Zheng, Swati Tanwar, Katsumasa Fujita, Ishan Barman
Förderung
- NIGMS NIH HHS
- Japan Science and Technology Agency
- National Institute of General Medical Sciences
Zitieren
APA
Lee, M. K. H., Mizushima, K., Zheng, P., Tanwar, S., Gupta, A., Fujita, K., & Barman, I. (2025). Spectrally Silent and Optically Transparent: Clear-SiR for Deep Raman Biomolecular Sensing. ACS Sensors. https://doi.org/10.1021/acssensors.5c02046
Vancouver
Lee MKH, Mizushima K, Zheng P, Tanwar S, Gupta A, Fujita K, et al. Spectrally Silent and Optically Transparent: Clear-SiR for Deep Raman Biomolecular Sensing. ACS Sensors. 2025. doi:10.1021/acssensors.5c02046
BibTeX
@article{Lee2025,
author = {Lee, Michael Ka Ho and Mizushima, Kenta and Zheng, Peng and Tanwar, Swati and Gupta, Anoushka and Fujita, Katsumasa and Barman, Ishan},
title = {Spectrally Silent and Optically Transparent: Clear-SiR for Deep Raman Biomolecular Sensing},
journal = {ACS Sensors},
year = {2025},
doi = {10.1021/acssensors.5c02046}
}
EUVIMED