EUVIMEDEUVIMED entdecken
Crossref

A Portable Dual-Mode Aptasensor for Rapid Detection of Influenza A Hemagglutinin

Abbey Koneru, Amit Kumar Barui, Malina Cantemir, Ana Maria Ulloa Gomez, Lia Stanciu iD

ACS Sensors · 2026

DOI: 10.1021/acssensors.5c02025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Abbey Koneru und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Influenza A virus, Biosensing Techniques, Hemagglutinin Glycoproteins, Influenza Virus. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Science Foundation Graduate Research Fellowship Program, Division of Chemical, Bioengineering, Environmental, and Transport Systems.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We report a highly portable dual modality aptasensing platform for the detection of surface glycoprotein, hemagglutinin (HA), of the influenza A virus. The sensing device consists of a colorimetric detection component composed of a microfluidic paper-based analytical device (μPAD) having four analyte testing areas, as well as a flexible, miniaturized three-electrode system. Both sensing components are brought together and encapsulated within a microfluidic holder, which increases the integrity of the device, mediates sample flow, and allows for ease of translation to point-of-care (POC) use. Colorimetric detection using the μPADs resulted in a detection limit of 0.62 μg/mL in buffer over a linear range of 0.75-50 μg/mL HA (R2 = 0.9905), with stability over 30 days (up to 97.3% signal retention). The electrochemical component uses impedance spectroscopy to measure changes in charge transfer resistance (Rct) upon aptamer-target recognition using hexaamineruthenium(III) chloride as a redox probe. Through the addition of the electrochemical component, the detection limit was improved to 8.5 ng/mL in buffer over a linear range of 0.015-25 μg/mL HA (R2 = 0.9730), with stability over 7 days (113.1% signal retention). When using the device with a modeled real sample medium of artificial human saliva, colorimetric analysis resulted in detection of HA down to 1.0 μg/mL, while the electrochemical component resulted in a detection limit of 14.9 ng/mL. Additionally, while carrying out tests in dilute human saliva composed of a fifty-fifty mixture of pooled human saliva and TE buffer, detection limits using the μPAD nearly matched the artificial saliva's calculated limit at 1.04 μg/mL and the electrochemical platform reached a comparable but even lower limit of detection at 4.11 ng/mL HA, displaying promise for real world applicability. Both sensing platforms exhibited excellent selectivity when used against other surface proteins of common viral pathogens. While using the combined device, there are five target-testing zones (4 colorimetric, 1 electrochemical), decreasing the likelihood of false-negative/false-positive outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideInfluenza A virusBiosensing TechniquesHemagglutinin Glycoproteins, Influenza VirusColorimetryHumansLimit of DetectionElectrochemical TechniquesRapid Diagnostic TestsDielectric Spectroscopy

Stichwörter der Autor:innen

aptamerbiosensorcolorimetric detectiondual-modalityelectrochemical detectionnanomaterialspoint-of-care

Substanzen

Aptamers, NucleotideHemagglutinin Glycoproteins, Influenza Virus

Autor:innen und Institutionen

  • Department of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States.
  • Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47906, United States.
  • Department of Biology, Grinnell College, Grinnell, Iowa 50112, United States.

ORCID-Profile: Lia Stanciu

Förderung

  • National Science Foundation Graduate Research Fellowship Program
  • Division of Chemical, Bioengineering, Environmental, and Transport Systems

Zitieren

APA

Koneru, A., Barui, A. K., Cantemir, M., Gomez, A. M. U., & Stanciu, L. (2026). A Portable Dual-Mode Aptasensor for Rapid Detection of Influenza A Hemagglutinin. ACS Sensors. https://doi.org/10.1021/acssensors.5c02025

Vancouver

Koneru A, Barui AK, Cantemir M, Gomez AMU, Stanciu L. A Portable Dual-Mode Aptasensor for Rapid Detection of Influenza A Hemagglutinin. ACS Sensors. 2026. doi:10.1021/acssensors.5c02025

BibTeX
@article{Koneru2026,
  author = {Koneru, Abbey and Barui, Amit Kumar and Cantemir, Malina and Gomez, Ana Maria Ulloa and Stanciu, Lia},
  title = {A Portable Dual-Mode Aptasensor for Rapid Detection of Influenza A Hemagglutinin},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.5c02025}
}
Kostenlos starten →