A novel dual-mode aptasensor based colorimetry and electrochemical detection of norovirus in fecal sample
Analytical Biochemistry · 2024
DOI: 10.1016/j.ab.2023.115444 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Biochemistry, 2024. Verfasst von Xinyue Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China. Hauptthemen laut MEDLINE: Norovirus, Aptamers, Nucleotide, Metal Nanoparticles, Biosensing Techniques. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Natural Science Foundation of Shanghai Municipality, National Natural Science Foundation of China.
Abstract (Originalsprache)
Norovirus is a leading cause of acute gastroenteritis in humans. This paper presents the development of a novel dual-mode aptasensor for detecting norovirus using colorimetry and electrochemical methods. The initial colorimetric method utilizes gold nanoparticles (AuNPs) and sodium chloride to establish a positive correlation between the concentration of norovirus in a solution and the absorbance ratio A650/A520. The naked eye can detect concentrations as low as 0.1 μg/mL, corresponding to a Ct value of 33 (2.2 copies/μL, CT = 34.102-3.2185·lgX), allowing for qualitative and semi-quantitative analysis. For more accurate trace analysis, a gold electrode is modified with a thiol-modified aptamer and closed with 6-Mercapto-1-hexanol. After incubation with norovirus, the virus specifically binds to the aptamer, causing changes in its spatial structure and distance from the electrode surface. These changes can then be detected using electrochemical square wave voltammetry (SWV). Under optimal reaction conditions, the peak current from SWV exhibits a strong linear relationship with the logarithm of norovirus concentrations between 10-9 μg/mL and 10-2 μg/mL. The regression equation Y = 14.76789 + 1.03983·lgX, with an R2 value of 0.987, accurately represents this relationship. The limit of detection was determined to be 1.365 × 10-10 μg/mL. Furthermore, the aptasensor demonstrated high specificity for norovirus in fecal samples, making it a promising tool for detecting norovirus in various sample types.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China.
- Shanghai Putuo District Disease Control Center, Shanghai, 200336, China.
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China. Electronic address: 267358918@qq.com.
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China. Electronic address: michaelyanzi@163.com.
Förderung
- Natural Science Foundation of Shanghai Municipality
- National Natural Science Foundation of China
Zitieren
APA
Li, X., Zhao, Y., Gu, W., Qian, Y., Huang, Q., Hu, X., & Xing, H. (2024). A novel dual-mode aptasensor based colorimetry and electrochemical detection of norovirus in fecal sample. Analytical Biochemistry. https://doi.org/10.1016/j.ab.2023.115444
Vancouver
Li X, Zhao Y, Gu W, Qian Y, Huang Q, Hu X, et al. A novel dual-mode aptasensor based colorimetry and electrochemical detection of norovirus in fecal sample. Analytical Biochemistry. 2024. doi:10.1016/j.ab.2023.115444
BibTeX
@article{Li2024,
author = {Li, Xinyue and Zhao, Yongqiang and Gu, Wenchao and Qian, Yong and Huang, Qi and Hu, Xiaojun and Xing, Haibo},
title = {A novel dual-mode aptasensor based colorimetry and electrochemical detection of norovirus in fecal sample},
journal = {Analytical Biochemistry},
year = {2024},
doi = {10.1016/j.ab.2023.115444}
}
EUVIMED