Highly Sensitive Detection of Engrailed-2 Protein Biomarker in Urine for Using Solution-Gated Graphene Transistor Diagnosis of Prostate Cancer
ACS Sensors · 28.03.2025 · 10 (3) · 2080-2089
DOI: 10.1021/acssensors.4c03320 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 04.03.2025. Verfasst von Junqi Dong und 9 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for the Green Preparation and Application of Functional Materials, Ministry of Education, Collaborative Innovation Center for Advanced…. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Graphite, Biosensing Techniques, Transistors, Electronic. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Overseas Expertise Introduction Center for Discipline Innovation of Food Nutrition and Human Health (111 Center), Department of Science and Technology, Hubei Provincial People's Government, Natural Science Foundation of Hubei Province.
Abstract (Originalsprache)
Engrailed-2 (EN2) protein, a transcription factor in the homologous domain expressed in prostate cancer (PCa) cells and secreted into the urine, is considered a promising biomarker for noninvasive detection of PCa. EN2 protein in urine samples can be obtained by noninvasive means, but the low biomarker concentration in urine samples poses a great challenge for noninvasive detection of the PCa biomarker. Herein, we develop a solution-gated graphene transistor (SGGT) biosensor to detect the biomarker of the EN2 protein for PCa diagnosis. The aptamer probes are immobilized to the gold gate electrode through Au-S bonds. The effect of aptamer configurations on the biosensor's responses is also investigated. It can be found that the SGGT biosensor with the long-chain probes with a stem-like loop structure exhibits optimal performance. The limit of detection of biosensors can reach 0.1 fg/mL, and a rapid response time of 19 min is achieved. The SGGT biosensor also exhibits high specificity for the EN2 protein. More importantly, testing of clinical urine samples indicates that our sensor can distinguish PCa patients from non-PCa subjects. Compared to traditional hospital prostate-specific antigen tests, our sensor exhibits better accuracy for the noninvasive diagnosis of PCa.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory for the Green Preparation and Application of Functional Materials, Ministry of Education, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministr…
- Department of Urology, Tongji Hospital, Tongji Medical College Huazhong, University of Science and Technology, Wuhan, 430030, P. R. China.
- School of Computer and Information Engineering, Hubei Normal University, Huangshi 435002, P. R. China.
ORCID-Profile: Xianbao Wang, Jinhua Li
Förderung
- Overseas Expertise Introduction Center for Discipline Innovation of Food Nutrition and Human Health (111 Center)
- Department of Science and Technology, Hubei Provincial People's Government
- Natural Science Foundation of Hubei Province
- Tongji Hospital
- Key Laboratory of Optoelectronic Chemical Materials and Devices
Zitieren
APA
Dong, J., Yang, H., Song, P., Yu, T., Pan, Z., Chen, Z., Wang, R., Deng, M., Wang, X., & Li, J. (2025). Highly Sensitive Detection of Engrailed-2 Protein Biomarker in Urine for Using Solution-Gated Graphene Transistor Diagnosis of Prostate Cancer. ACS Sensors, 10(3), 2080-2089. https://doi.org/10.1021/acssensors.4c03320
Vancouver
Dong J, Yang H, Song P, Yu T, Pan Z, Chen Z, et al. Highly Sensitive Detection of Engrailed-2 Protein Biomarker in Urine for Using Solution-Gated Graphene Transistor Diagnosis of Prostate Cancer. ACS Sensors. 2025;10(3):2080-2089. doi:10.1021/acssensors.4c03320
BibTeX
@article{Dong2025,
author = {Dong, Junqi and Yang, Huan and Song, Peng and Yu, Tingting and Pan, Zexun and Chen, Ziwen and Wang, Ruixue and Deng, Minghua and Wang, Xianbao and Li, Jinhua},
title = {Highly Sensitive Detection of Engrailed-2 Protein Biomarker in Urine for Using Solution-Gated Graphene Transistor Diagnosis of Prostate Cancer},
journal = {ACS Sensors},
year = {2025},
volume = {10},
number = {3},
pages = {2080--2089},
doi = {10.1021/acssensors.4c03320}
}
EUVIMED