An Integrated Graphene‐MXene Electrochemical Transistor Array Platform for Accurate Prostate Cancer Diagnosis Using Plasma sEV‐Derived E2F5 Biomarker
Small · 2026-06 · 22 (32)
DOI: 10.1002/smll.73543 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small, online erschienen am 30.04.2026. Verfasst von Piyali Mukherjee und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics & Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Howrah, West Bengal, India. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Graphite, Biomarkers, Tumor, Exosomes. Die Arbeit nennt 43 Literaturangaben. Gefördert von: MHRD, Govt. of India, ANRF-PAIR, New Delhi, Indian Council of Medical Research, New Delhi.
Abstract (Originalsprache)
Exosomes have been investigated for the diagnosis of prostate cancer (PC) due to their capability of offering a real‐time reflection of tumor burden. However, discriminating benign prostatic hyperplasia (BPH) from healthy controls (HC) and varying PC grades remains a challenge in clinical settings. Here, an ultrasensitive electrochemical field‐effect transistor based on porous graphene‐MXene composites has been constructed that circumvents the Debye screening limitations in detecting large biomolecular targets like exosomes. Additionally, the device leverages synergistic interfacial effects to enhance receptor binding density, which contributes to high sensitivity, leading to a detection limit of 200 exosomes/ml (approximately three orders of magnitude lower than the most sensitive antibody‐based reports), with a wide range (∼10 8 exosomes/ml) and detection time within 30 min. Further, dielectrophoresis (DEP) enabled in situ exosome enrichment is integrated, enabling direct analysis of clinical samples without ultracentrifugation. Most importantly, the efficacy of E2F5 as an exosomal protein has been validated for accurate PC diagnosis in all patient cohorts. Multiple features have been extracted from the sensor response and analyzed using an ensemble classification method. Interestingly, the outcomes reveal that the sensor successfully distinguished BPH from HCs with appreciable accuracy of 91.11% and shows similar diagnostic performance with lower grade PC, higher grade PC, and healthy patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electronics & Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Howrah, West Bengal, India.
- Department of Biochemistry, University of Calcutta, Kolkata, West Bengal, India.
- Materials Chemistry & Interfacial Engineering Department, CSIR-Institute of Minerals and Materials Technology, Bhubaneswar, Odisha, India.
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India.
- Applied Materials and Instrumentation, CSIR-Central Scientific Instruments Organisation, Chandigarh, Punjab, India.
- School of Advanced Material Engineering, Kookmin University, Seoul, Republic of Korea.
ORCID-Profile: Piyali Mukherjee, Nahid Sultana, Ghrutanjali Sahu, Laxmidhar Besra, Pritam Das, Sanghamitra Sengupta, Sriparna Chatterjee, Chirasree RoyChaudhuri
Förderung
- MHRD, Govt. of India
- ANRF-PAIR, New Delhi
- Indian Council of Medical Research, New Delhi
- CSIR
- Council of Scientific and Industrial Research, India
Zitieren
APA
Mukherjee, P., Sultana, N., Sahu, G., Goyal, I., Besra, L., Das, P., Sarkar, D., Bishnu, D., Devi, P., Sengupta, S., Chatterjee, S., & RoyChaudhuri, C. (2026). An Integrated Graphene‐MXene Electrochemical Transistor Array Platform for Accurate Prostate Cancer Diagnosis Using Plasma sEV‐Derived E2F5 Biomarker. Small, 22(32). https://doi.org/10.1002/smll.73543
Vancouver
Mukherjee P, Sultana N, Sahu G, Goyal I, Besra L, Das P, et al. An Integrated Graphene‐MXene Electrochemical Transistor Array Platform for Accurate Prostate Cancer Diagnosis Using Plasma sEV‐Derived E2F5 Biomarker. Small. 2026;22(32). doi:10.1002/smll.73543
BibTeX
@article{Mukherjee2026,
author = {Mukherjee, Piyali and Sultana, Nahid and Sahu, Ghrutanjali and Goyal, Isha and Besra, Laxmidhar and Das, Pritam and Sarkar, Debansu and Bishnu, Debasree and Devi, Pooja and Sengupta, Sanghamitra and Chatterjee, Sriparna and RoyChaudhuri, Chirasree},
title = {An Integrated Graphene‐MXene Electrochemical Transistor Array Platform for Accurate Prostate Cancer Diagnosis Using Plasma sEV‐Derived E2F5 Biomarker},
journal = {Small},
year = {2026},
volume = {22},
number = {32},
doi = {10.1002/smll.73543}
}
EUVIMED