A Nonfouling Electrochemical Biosensor for Protein Analysis in Complex Body Fluids Based on Multifunctional Peptide Conjugated with PEGlyated Phospholipid
ACS Sensors · 2024
DOI: 10.1021/acssensors.4c02425 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Yang Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of …. Hauptthemen laut MEDLINE: Biosensing Techniques, Peptides, Electrochemical Techniques, Polyethylene Glycols. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Technology Research and Development Program of Shandong Province.
Abstract (Originalsprache)
Developing antifouling biosensors capable of performing robustly in complex human body fluids is crucial for biomarker diagnosis and health monitoring. Herein, an antifouling and highly sensitive and stable biosensor was constructed through the self-assembly of the designed conjugates composed of a multifunctional peptide (MP) and PEGylated distearoylphosphatidylethanolamine (DSPE-PEG). The self-assembly capability of the DSPE-PEG-MP was demonstrated clearly through coarse-grained molecular dynamics simulation and transmission electron microscopy, and it can be effectively self-assembled onto the electrode surface modified with gold nanoparticles. The MP was designed to be antifouling and contained a peptide sequence that can specifically bind the target protein Annexin A1 (ANXA1), and the D-type amino acid composition of MP can enhance its resistance to enzymatic hydrolysis. The unique design of MP, in conjugation with the self-assembly capability of the PEGylated phospholipid DSPE-PEG, enabled the biosensor to exhibit excellent antifouling capability and stability in various complex human body fluids. The biosensor was capable of sensitively and selectively quantifying ANXA1 and achieved a limit of detection down to 0.12 pg mL-1. More importantly, the biosensor demonstrated satisfactory accuracy for ANXA1 detection in clinical serum samples, as verified by the enzyme linked immunosorbent assay (ELISA) kits. It is expected that various antifouling biosensors suitable for application in complex biological environments can be constructed by utilizing the strategy of designing similar DSPE-PEG-MP conjugates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and…
ORCID-Profile: Xiliang Luo
Förderung
- National Natural Science Foundation of China
- Key Technology Research and Development Program of Shandong Province
Zitieren
APA
Li, Y., Han, R., Zhu, B., Wang, W., Song, Z., & Luo, X. (2024). A Nonfouling Electrochemical Biosensor for Protein Analysis in Complex Body Fluids Based on Multifunctional Peptide Conjugated with PEGlyated Phospholipid. ACS Sensors. https://doi.org/10.1021/acssensors.4c02425
Vancouver
Li Y, Han R, Zhu B, Wang W, Song Z, Luo X. A Nonfouling Electrochemical Biosensor for Protein Analysis in Complex Body Fluids Based on Multifunctional Peptide Conjugated with PEGlyated Phospholipid. ACS Sensors. 2024. doi:10.1021/acssensors.4c02425
BibTeX
@article{Li2024,
author = {Li, Yang and Han, Rui and Zhu, Baoping and Wang, Wenqing and Song, Zhen and Luo, Xiliang},
title = {A Nonfouling Electrochemical Biosensor for Protein Analysis in Complex Body Fluids Based on Multifunctional Peptide Conjugated with PEGlyated Phospholipid},
journal = {ACS Sensors},
year = {2024},
doi = {10.1021/acssensors.4c02425}
}
EUVIMED