Ultrasensitive Electrochemical Vertical Flow Immunoassay for Rapid and Simultaneous Detection of Interleukin-6 and Procalcitonin
ACS Sensors · 27.12.2024 · 9 (12) · 6667-6674
DOI: 10.1021/acssensors.4c02257 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 05.12.2024. Verfasst von Xudong Ying und 5 weiteren Autor:innen. Beteiligte Einrichtung: General Surgery Department, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou…. Hauptthemen laut MEDLINE: Procalcitonin, Interleukin-6, Electrochemical Techniques, Limit of Detection. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Rapid and multiplexed detection of biomarkers plays an indispensable role in disease diagnosis. Although paper-based lateral flow immunoassays have been widely used in this field, the speediness and throughput are still challenging issues. Herein, an electrochemical vertical flow immunoassay device (eVFID) is fabricated for rapid, ultrasensitive, and multiplexed detection of inflammatory biomarkers. Working electrodes with excellent electrochemical performance and permeability properties were directly fabricated on the nitrocellulose membrane to enable both the vertical flow of the sample solution and electrochemical detection. This vertical configuration can remarkably improve the speediness of the immunoassay and effectively inhibit the cross-talk reactions among immunomolecules, thus allowing rapid and simultaneous detection of multiplexed biomarkers. Furthermore, a signal amplification strategy based on horseradish peroxidase and tetramethylbenzidine was integrated into the eVFID to substantially increase the sensitivity of the electrochemical detection. A low limit of detection of 0.1 and 0.22 pg mL-1 was obtained for two low-abundance inflammatory biomarkers, interleukin-6 (IL-6) and procalcitonin (PCT), respectively. Finally, using a two-channel eVFID, simultaneous detection of IL-6 and PCT in human plasma samples was successfully realized within 5 min. We believe that the eVFID holds great promise for speedy and high-throughput biomarker detection at the point of care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- General Surgery Department, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, China.
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
- Department of Clinical Laboratory, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, China.
ORCID-Profile: Bin Su
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Ying, X., Fu, W., Qi, M., Zhou, L., Li, W., & Su, B. (2024). Ultrasensitive Electrochemical Vertical Flow Immunoassay for Rapid and Simultaneous Detection of Interleukin-6 and Procalcitonin. ACS Sensors, 9(12), 6667-6674. https://doi.org/10.1021/acssensors.4c02257
Vancouver
Ying X, Fu W, Qi M, Zhou L, Li W, Su B. Ultrasensitive Electrochemical Vertical Flow Immunoassay for Rapid and Simultaneous Detection of Interleukin-6 and Procalcitonin. ACS Sensors. 2024;9(12):6667-6674. doi:10.1021/acssensors.4c02257
BibTeX
@article{Ying2024,
author = {Ying, Xudong and Fu, Wenxuan and Qi, Min and Zhou, Lin and Li, Wei and Su, Bin},
title = {Ultrasensitive Electrochemical Vertical Flow Immunoassay for Rapid and Simultaneous Detection of Interleukin-6 and Procalcitonin},
journal = {ACS Sensors},
year = {2024},
volume = {9},
number = {12},
pages = {6667--6674},
doi = {10.1021/acssensors.4c02257}
}
EUVIMED