A Facile Way to Simultaneously Improve Humidity-Immunity and Gas Response in Semiconductor Metal Oxide Sensors
ACS Sensors · 27.12.2024 · 9 (12) · 6441-6449
DOI: 10.1021/acssensors.4c01712 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 29.10.2024. Verfasst von Jieon Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Functional Materials & Components R&D group, Korea Institute of Industrial Technology (KITECH), 137-41 Gwahakdanji-ro, Gangneung-si, Gangwon 25440, R…. Hauptthemen laut MEDLINE: Humidity, Oxides, Semiconductors, Ammonia. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Research Foundation of Korea, Korea Institute of Science and Technology, Korea Institute of Industrial Technology.
Abstract (Originalsprache)
The metal-oxide-based gas sensors show great potential in exhaled breath analysis owing to their simple, fast, and noninvasive characteristics. However, the exhaled breath contains moisture, and the surface-active sites of metal oxides are easily poisoned by water molecules, leading to degradation of the sensor performance, particularly the gas response and selectivity. Therefore, it is essential to develop oxide sensors that can reliably sense target gases over a wide humidity range without sacrificing the gas response. In this study, a facile strategy was proposed to incorporate hydrophobic La into an oxide sensor to simultaneously improve the humidity-stability and sensitivity of NH3 detection for early prediction of kidney failure. WO3 sensors doped with various concentrations of La were successfully synthesized, and their gas-sensing performances under various humid conditions were systematically investigated. Interestingly, a small amount of La doping (1 at. %) effectively prevented water poisoning and improved the gas response simultaneously. This sensor was able to selectively detect NH3 up to 200 ppb with a limit of detection (LOD) of ∼780 ppt over a wide range of humidity. The concurrent enhancement in gas response and humidity-immunity was attributed to the surface hydrophobicity and increased specific surface area caused by the incorporation of La.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Functional Materials & Components R&D group, Korea Institute of Industrial Technology (KITECH), 137-41 Gwahakdanji-ro, Gangneung-si, Gangwon 25440, Republic of Korea.
- Computational Science Research Center, Korea Institute of Science and Technology (KIST), 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea.
- Department of Materials Science and Engineering, Kyonggi University, 154-42, Gwanggyosan-ro, Suwon, Gyeonggi 16227, Republic of Korea.
ORCID-Profile: Sangwoo Ryu, Young Kyu Jeong
Förderung
- National Research Foundation of Korea
- Korea Institute of Science and Technology
- Korea Institute of Industrial Technology
- National Supercomputing Center, Korea Institute of Science and Technology Information
Zitieren
APA
Lee, J., Din, H. U., Ham, M. J., Song, Y., Lee, J. H., Kwon, Y. J., Ryu, S., & Jeong, Y. K. (2024). A Facile Way to Simultaneously Improve Humidity-Immunity and Gas Response in Semiconductor Metal Oxide Sensors. ACS Sensors, 9(12), 6441-6449. https://doi.org/10.1021/acssensors.4c01712
Vancouver
Lee J, Din HU, Ham MJ, Song Y, Lee JH, Kwon YJ, et al. A Facile Way to Simultaneously Improve Humidity-Immunity and Gas Response in Semiconductor Metal Oxide Sensors. ACS Sensors. 2024;9(12):6441-6449. doi:10.1021/acssensors.4c01712
BibTeX
@article{Lee2024,
author = {Lee, Jieon and Din, Haleem Ud and Ham, Min Ji and Song, Yeonghwan and Lee, Jung-Hoon and Kwon, Yong Jung and Ryu, Sangwoo and Jeong, Young Kyu},
title = {A Facile Way to Simultaneously Improve Humidity-Immunity and Gas Response in Semiconductor Metal Oxide Sensors},
journal = {ACS Sensors},
year = {2024},
volume = {9},
number = {12},
pages = {6441--6449},
doi = {10.1021/acssensors.4c01712}
}
EUVIMED