Observation of Concentration-Dependent Inversion of Response to Oxidizing Gases in Chemoresistive Metal Oxide Gas Sensors Resulting from Humidity Interference
ACS Sensors · 27.02.2026 · 11 (2) · 1106-1116
DOI: 10.1021/acssensors.5c02990 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 06.02.2026. Verfasst von Pengfei Zhou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Special Functional Materials for Ecological Environment and Information, Hebei University of Technology, Ministry of Education, Tia…. Hauptthemen laut MEDLINE: Humidity, Oxides, Gases, Chromium Compounds. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, Natural Science Foundation of Hebei Province, China Scholarship Council.
Abstract (Originalsprache)
High Resolution Image Download MS PowerPoint Slide Chemoresistive metal oxide gas sensors typically exhibit predictable resistance changes upon exposure to oxidizing or reducing gases, depending on their semiconductor type. However, anomalous concentration-dependent inversion of response has been reported, often attributed to intrinsic material properties. In this study, we investigate such inversion phenomena in Cr 2 O 3 -based sensors doped with Ti(IV), W(VI), and Ni(II), alongside Ag-decorated WO 3 sensors. Initial observations suggested inversion of response to low concentrations of O 2, consistent with prior hypotheses involving carrier-type transitions. However, systematic experiments revealed that this inversion was not intrinsic but rather caused by trace water contamination in the analyte gas stream. Only through cryogenic drying of the analyte gases was the expected sensor behavior restored. Mass spectrometry confirmed water as the sole contaminant responsible. Further tests demonstrated that water induces a rapid resistance increase in p -type Cr 2 O 3 sensors, mimicking an n -type response. These findings highlight the critical influence of humidity on sensor behavior and suggest that some previously reported inversion phenomena may stem from undetected water interference. This work underscores the necessity of rigorous gas stream purification in low-concentration gas sensing studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Special Functional Materials for Ecological Environment and Information, Hebei University of Technology, Ministry of Education, Tianjin 300130, China.
- Department of Chemistry, University College London, London WC1H 0AJ, United Kingdom.
- School of Resources and Civil Engineering, Northeastern University, Shenyang 110819, China.
ORCID-Profile: Michael Parkes, Christopher S Blackman
Förderung
- Engineering and Physical Sciences Research Council
- Natural Science Foundation of Hebei Province
- China Scholarship Council
Zitieren
APA
Zhou, P., Tsang, J. H., Zhu, Y., Parkes, M., Shen, Y., & Blackman, C. S. (2026). Observation of Concentration-Dependent Inversion of Response to Oxidizing Gases in Chemoresistive Metal Oxide Gas Sensors Resulting from Humidity Interference. ACS Sensors, 11(2), 1106-1116. https://doi.org/10.1021/acssensors.5c02990
Vancouver
Zhou P, Tsang JH, Zhu Y, Parkes M, Shen Y, Blackman CS. Observation of Concentration-Dependent Inversion of Response to Oxidizing Gases in Chemoresistive Metal Oxide Gas Sensors Resulting from Humidity Interference. ACS Sensors. 2026;11(2):1106-1116. doi:10.1021/acssensors.5c02990
BibTeX
@article{Zhou2026,
author = {Zhou, Pengfei and Tsang, Jone-Him and Zhu, Yiyun and Parkes, Michael and Shen, Yanbai and Blackman, Christopher S},
title = {Observation of Concentration-Dependent Inversion of Response to Oxidizing Gases in Chemoresistive Metal Oxide Gas Sensors Resulting from Humidity Interference},
journal = {ACS Sensors},
year = {2026},
volume = {11},
number = {2},
pages = {1106--1116},
doi = {10.1021/acssensors.5c02990}
}
EUVIMED