Ppb-Level Ammonia Sensor for Exhaled Breath Diagnosis Based on UV-DOAS Combined with Spectral Reconstruction Fitting Neural Network

Rui Zhu, Qiwen Zhou, Qi Tian, Shuo Zhao, Wanyi Qin, Xijun Wu, Shufeng Xu, Yungang Zhang iD

ACS Sensors · 2024

DOI: 10.1021/acssensors.4c01525 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Rui Zhu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China. Hauptthemen laut MEDLINE: Ammonia, Breath Tests, Neural Networks, Computer. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Natural Science Foundation of Hebei Province, National Natural Science Foundation of China, Central Government Guides Local Science and Technology Development Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ammonia (NH3) in exhaled breath (EB) has been a biomarker for kidney function, and accurate measurement of NH3 is essential for early screening of kidney disease. In this work, we report an optical sensor that combines ultraviolet differential optical absorption spectroscopy (UV-DOAS) and spectral reconstruction fitting neural network (SRFNN) for detecting NH3 in EB. UV-DOAS is introduced to eliminate interference from slow change absorption in the EB spectrum while spectral reconstruction fitting is proposed for the first time to map the original spectra onto the sine function spectra by the principle of least absolute deviations. The sine function spectra are then fitted by the least-squares method to eliminate noise signals and the interference of exhaled nitric oxide. Finally, the neural network is built to enable the detection of NH3 in EB at parts per billion (ppb) level. The laboratory results show that the detection range is 9.50-12425.82 ppb, the mean absolute percentage error (MAPE) is 0.83%, and the detection accuracy is 0.42%. Experimental results prove that the sensor can detect breath NH3 and identify EB in simulated patients and healthy people. Our sensor will serve as a new and effective system for detecting breath NH3 with high accuracy and stability in the medical field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmmoniaBreath TestsNeural Networks, ComputerHumansSpectrophotometry, UltravioletExhalation

Stichwörter der Autor:innen

ammoniaexhaled breathoptical sensorspectral reconstruction fitting neural networkultraviolet differential optical absorption spectroscopy

Substanzen

Ammonia

Autor:innen und Institutionen

  • School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • Department of Pulmonary and Critical Care Medicine, The First Hospital of Qinhuangdao, Qinhuangdao, Hebei 066000, China.

ORCID-Profile: Yungang Zhang

Förderung

  • Natural Science Foundation of Hebei Province
  • National Natural Science Foundation of China
  • Central Government Guides Local Science and Technology Development Foundation

Zitieren

APA

Zhu, R., Zhou, Q., Tian, Q., Zhao, S., Qin, W., Wu, X., Xu, S., & Zhang, Y. (2024). Ppb-Level Ammonia Sensor for Exhaled Breath Diagnosis Based on UV-DOAS Combined with Spectral Reconstruction Fitting Neural Network. ACS Sensors. https://doi.org/10.1021/acssensors.4c01525

Vancouver

Zhu R, Zhou Q, Tian Q, Zhao S, Qin W, Wu X, et al. Ppb-Level Ammonia Sensor for Exhaled Breath Diagnosis Based on UV-DOAS Combined with Spectral Reconstruction Fitting Neural Network. ACS Sensors. 2024. doi:10.1021/acssensors.4c01525

BibTeX
@article{Zhu2024,
  author = {Zhu, Rui and Zhou, Qiwen and Tian, Qi and Zhao, Shuo and Qin, Wanyi and Wu, Xijun and Xu, Shufeng and Zhang, Yungang},
  title = {Ppb-Level Ammonia Sensor for Exhaled Breath Diagnosis Based on UV-DOAS Combined with Spectral Reconstruction Fitting Neural Network},
  journal = {ACS Sensors},
  year = {2024},
  doi = {10.1021/acssensors.4c01525}
}
Kostenlos starten →