An exhaled breath gas sensor system for near-infrared ammonia measurement and kidney diagnostics
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2024
DOI: 10.1016/j.saa.2024.124625 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2024. Verfasst von Kaiyuan Zheng und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 1…. Hauptthemen laut MEDLINE: Breath Tests, Ammonia, Spectroscopy, Near-Infrared. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jilin Provincial Scientific and Technological Development Program, National Key Research and Development Program of China.
Abstract (Originalsprache)
Breath analysis enables rapid, noninvasive diagnosis of human health by identifying and quantifying exhaled biomarker. Here, we demonstrated an exhaled breath sensing method using the near-infrared laser spectroscopy, and sub parts-per-million (ppm) level ammonia detection inside the exhaled gas was achieved employing a distributed feedback laser centered at 1512 nm and Kalman filtering algorithm. Integration of the ammonia sensor was realized for exhaled breath analysis of kidney patients, and a dual operation mechanism with static and dynamic modes was proposed to make this method applicable for real-time and comprehensive pre-diagnosis of kidney disease.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China; Kaiyuan Zheng and Lei Zhang contributed equally to this…
- Center of Interventional Radiology and Vascular Surgery, Department of Radiology, Zhongda Hospital, Medical School, Southeast University, China.
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China.
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China. Electronic address: ZHENGCHUANTAO@JLU.EDU.CN.
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston TX 77005, USA.
Förderung
- National Natural Science Foundation of China
- Jilin Provincial Scientific and Technological Development Program
- National Key Research and Development Program of China
Zitieren
APA
Zheng, K., Zhang, L., Leng, S., Xi, Z., Zheng, C., Wang, Y., & Tittel, F. K. (2024). An exhaled breath gas sensor system for near-infrared ammonia measurement and kidney diagnostics. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2024.124625
Vancouver
Zheng K, Zhang L, Leng S, Xi Z, Zheng C, Wang Y, et al. An exhaled breath gas sensor system for near-infrared ammonia measurement and kidney diagnostics. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2024. doi:10.1016/j.saa.2024.124625
BibTeX
@article{Zheng2024,
author = {Zheng, Kaiyuan and Zhang, Lei and Leng, Shuo and Xi, Zhenhai and Zheng, Chuantao and Wang, Yiding and Tittel, Frank K},
title = {An exhaled breath gas sensor system for near-infrared ammonia measurement and kidney diagnostics},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2024},
doi = {10.1016/j.saa.2024.124625}
}
EUVIMED