EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy

Qianyu Wang, Águeda Molinero-Fernandez, Qikun Wei, Xing Xuan, Åsa Konradsson-Geuken, María Cuartero iD, Gastón A Crespo iD

ACS Sensors · 28.06.2024 · 9 (6) · 3115-3125

DOI: 10.1021/acssensors.4c00337 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 23.05.2024. Verfasst von Qianyu Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden. Hauptthemen laut MEDLINE: Lactic Acid, Needles. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Vetenskapsr?det, Carl Tryggers Stiftelse f?r Vetenskaplig Forskning, Olle Engkvists Stiftelse.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lactate is an important diagnostic and prognostic biomarker of several human pathological conditions, such as sepsis, malaria, and dengue fever. Unfortunately, due to the lack of reliable analytical decentralized platforms, the determination of lactate yet relies on discrete blood-based assays, which are invasive and inefficient and may cause tension and pain in the patient. Herein, we demonstrate the potential of a fully integrated microneedle (MN) sensing system for the minimally invasive transdermal detection of lactate in an interstitial fluid (ISF). The originality of this analytical technology relies on: (i) a strategy to provide a uniform coating of a doped polymer-based membrane as a diffusion-limiting layer on the MN structure, optimized to perform full-range lactate detection in the ISF (linear range of response: 0.25-35 mM, 30 s assay time, 8 h operation), (ii) double validation of ex vivo and in vivo results based on ISF and blood measurements in rats, (iii) monitoring of lactate level fluctuations under the administration of anesthesia to mimic bedside clinical scenarios, and (iv) in-house design and fabrication of a fully integrated and portable sensing device in the form of a wearable patch including a custom application and user-friendly interface in a smartphone for the rapid, routine, continuous, and real-time lactate monitoring. The main analytical merits of the lactate MN sensor include appropriate selectivity, reversibility, stability, and durability by using a two-electrode amperometric readout. The ex-vivo testing of the MN patch of preconditioned rat skin pieces and euthanized rats successfully demonstrated the accuracy in measuring lactate levels. The in vivo measurements suggested the existence of a positive correlation between ISF and blood lactate when a lag time of 10 min is considered (Pearson's coefficient = 0.85, mean difference = 0.08 mM). The developed MN-based platform offers distinct advantages over noncontinuous blood sampling in a wide range of contexts, especially where access to laboratory services is limited or blood sampling is not suitable. Implementation of the wearable patch in healthcare could envision personalized medicine in a variety of clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lactic AcidNeedlesAnimalsRatsBiosensing TechniquesExtracellular FluidRats, Sprague-DawleySkinMaleHumans

Stichwörter der Autor:innen

electrochemical sensorinterstitial fluid lactateintradermal measurementwearable sensorwearable validation

Substanzen

Lactic Acid

Autor:innen und Institutionen

  • Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden.
  • UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain.
  • Section of Neuropharmacology and Addiction Research, Department of Pharmaceutical Biosciences, Uppsala University, SE-751 05 Uppsala, Sweden.

ORCID-Profile: María Cuartero, Gastón A Crespo

Förderung

  • Vetenskapsr?det
  • Carl Tryggers Stiftelse f?r Vetenskaplig Forskning
  • Olle Engkvists Stiftelse
  • China Scholarship Council

Zitieren

APA

Wang, Q., Molinero-Fernandez, Á., Wei, Q., Xuan, X., Konradsson-Geuken, Å., Cuartero, M., & Crespo, G. A. (2024). Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy. ACS Sensors, 9(6), 3115-3125. https://doi.org/10.1021/acssensors.4c00337

Vancouver

Wang Q, Molinero-Fernandez Á, Wei Q, Xuan X, Konradsson-Geuken Å, Cuartero M, et al. Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy. ACS Sensors. 2024;9(6):3115-3125. doi:10.1021/acssensors.4c00337

BibTeX
@article{Wang2024,
  author = {Wang, Qianyu and Molinero-Fernandez, Águeda and Wei, Qikun and Xuan, Xing and Konradsson-Geuken, Åsa and Cuartero, María and Crespo, Gastón A},
  title = {Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy},
  journal = {ACS Sensors},
  year = {2024},
  volume = {9},
  number = {6},
  pages = {3115--3125},
  doi = {10.1021/acssensors.4c00337}
}
Kostenlos starten →