Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 22.01.2024. Verfasst von Muamer Dervisevic und 4 weiteren Autor:innen. Beteiligte Einrichtung: Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia. Hauptthemen laut MEDLINE: Extracellular Fluid, Wearable Electronic Devices. Die Arbeit wurde bisher 67-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Australian Research Council, Alexander von Humboldt-Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microneedle-based wearable electrochemical biosensors are the new frontier in personalized health monitoring and disease diagnostic devices that provide an alternative tool to traditional blood-based invasive techniques. Advancements in micro- and nanofabrication technologies enabled the fabrication of microneedles using different biomaterials and morphological features with the aim of overcoming existing challenges and enhancing sensing performance. In this work, we report a microneedle array featuring conductive recessed microcavities for monitoring urea levels in the interstitial fluid of the skin. Microcavities are small pockets on the tip of each microneedle that can accommodate the sensing layer, provide protection from delamination during skin insertion or removal, and position the sensing layer in a deep layer of the skin to reach the interstitial fluid. The wearable urea patch has shown to be highly sensitive and selective in monitoring urea, with a sensitivity of 2.5 mV mM-1 and a linear range of 3 to 18 mM making it suitable for monitoring urea levels in healthy individuals and patients. Our ex vivo experiments have shown that recessed microcavities can protect the sensing layer from delamination during skin insertion and monitor changing urea levels in interstitial fluid. This biocompatible platform provides alternative solutions to the critical issue of maintaining the performance of the biosensor upon skin insertion and holds great potential for advancing transdermal sensor technology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracellular FluidWearable Electronic DevicesHumansSkinBiocompatible MaterialsUrea

Stichwörter der Autor:innen

biosensorinterstitial fluidmicrocavitiesmicroneedle arrayskinureawearable

Substanzen

Biocompatible MaterialsUrea

Autor:innen und Institutionen

  • Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.
  • Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria 3168, Australia.
  • Materials Science and Engineering, Monash University, Clayton, Victoria 3168, Australia.

ORCID-Profile: Muamer Dervisevic, Maximiliano Jesus Jara Fornerod, Nicolas H Voelcker

Förderung

  • Australian Research Council
  • Alexander von Humboldt-Stiftung

Zitieren

APA

Dervisevic, M., Jara Fornerod, M. J., Harberts, J., Zangabad, P. S., & Voelcker, N. H. (2024). Wearable Microneedle Patch for Transdermal Electrochemical Monitoring of Urea in Interstitial Fluid. ACS Sensors, 9(2), 932-941. https://doi.org/10.1021/acssensors.3c02386

Vancouver

Dervisevic M, Jara Fornerod MJ, Harberts J, Zangabad PS, Voelcker NH. Wearable Microneedle Patch for Transdermal Electrochemical Monitoring of Urea in Interstitial Fluid. ACS Sensors. 2024;9(2):932-941. doi:10.1021/acssensors.3c02386

BibTeX
@article{Dervisevic2024,
  author = {Dervisevic, Muamer and Jara Fornerod, Maximiliano Jesus and Harberts, Jann and Zangabad, Parham Sahandi and Voelcker, Nicolas H},
  title = {Wearable Microneedle Patch for Transdermal Electrochemical Monitoring of Urea in Interstitial Fluid},
  journal = {ACS Sensors},
  year = {2024},
  volume = {9},
  number = {2},
  pages = {932--941},
  doi = {10.1021/acssensors.3c02386}
}
Kostenlos starten →