Demonstrating the Analytical Potential of a Wearable Microneedle-Based Device for Intradermal CO 2 Detection
ACS Sensors · 2024
DOI: 10.1021/acssensors.3c02086 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Águeda Molinero-Fernandez und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden. Hauptthemen laut MEDLINE: Carbon Dioxide, Wearable Electronic Devices. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Vetenskapsr?det, Carl Tryggers Stiftelse f?r Vetenskaplig Forskning, Olle Engkvists Stiftelse.
Abstract (Originalsprache)
Monitoring of carbon dioxide (CO2) body levels is crucial under several clinical conditions (e.g., human intensive care and acid-base disorders). To date, painful and risky arterial blood punctures have been performed to obtain discrete CO2 measurements needed in clinical setups. Although noninvasive alternatives have been proposed to assess CO2, these are currently limited to benchtop devices, requiring trained personnel, being tedious, and providing punctual information, among other disadvantages. To the best of our knowledge, the literature and market lack a wearable device for real-time, on-body monitoring of CO2. Accordingly, we have developed a microneedle (MN)-based sensor array, labeled as CO2-MN, comprising a combination of potentiometric pH- and carbonate (CO32-)-selective electrodes together with the reference electrode. The CO2-MN is built on an epidermal patch that allows it to reach the stratum corneum of the skin, measuring pH and CO32- concentrations directly into the interstitial fluid (ISF). The levels for the pH-CO32- tandem are then used to estimate the PCO2 in the ISF. Assessing the response of each individual MN, we found adequate response time (t95 < 5s), sensitivity (50.4 and -24.6 mV dec-1 for pH and CO32-, respectively), and stability (1.6 mV h-1 for pH and 2.1 mV h-1 for CO32-). We validated the intradermal measurements of CO2 at the ex vivo level, using pieces of rat skin, and then, with in vivo assays in anesthetized rats, showing the suitability of the CO2-MN wearable device for on-body measurements. A good correlation between ISF and blood CO2 concentrations was observed, demonstrating the high potential of the developed MN sensing technology as an alternative to blood-based analysis in the near future. Moreover, these results open new horizons in the noninvasive, real-time monitoring of CO2 as well as other clinically relevant gases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden.
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain.
- Section of Neuropharmacology and Addiction Research, Department of Pharmaceutical Biosciences, Uppsala University, Uppsala 753 10, Sweden.
ORCID-Profile: Gastón A Crespo, María Cuartero
Förderung
- Vetenskapsr?det
- Carl Tryggers Stiftelse f?r Vetenskaplig Forskning
- Olle Engkvists Stiftelse
- China Scholarship Council
- Region of Stockholm
Zitieren
APA
Molinero-Fernandez, Á., Wang, Q., Xuan, X., Konradsson-Geuken, Å., Crespo, G. A., & Cuartero, M. (2024). Demonstrating the Analytical Potential of a Wearable Microneedle-Based Device for Intradermal CO 2 Detection. ACS Sensors. https://doi.org/10.1021/acssensors.3c02086
Vancouver
Molinero-Fernandez Á, Wang Q, Xuan X, Konradsson-Geuken Å, Crespo GA, Cuartero M. Demonstrating the Analytical Potential of a Wearable Microneedle-Based Device for Intradermal CO 2 Detection. ACS Sensors. 2024. doi:10.1021/acssensors.3c02086
BibTeX
@article{MolineroFernandez2024,
author = {Molinero-Fernandez, Águeda and Wang, Qianyu and Xuan, Xing and Konradsson-Geuken, Åsa and Crespo, Gastón A and Cuartero, María},
title = {Demonstrating the Analytical Potential of a Wearable Microneedle-Based Device for Intradermal CO 2 Detection},
journal = {ACS Sensors},
year = {2024},
doi = {10.1021/acssensors.3c02086}
}
EUVIMED