EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Review of Noninvasive Continuous Glucose Monitoring in Diabetics

Yilin Li, Yueyue Chen iD

ACS Sensors · 27.10.2023 · 8 (10) · 3659-3679

DOI: 10.1021/acssensors.3c01538 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift ACS Sensors, online erschienen am 16.10.2023. Verfasst von Yilin Li und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, Beijing, 100069, PR China. Hauptthemen laut MEDLINE: Diabetes Mellitus, Wearable Electronic Devices. Die Arbeit wurde bisher 84-mal zitiert (Crossref) und nennt 144 Literaturangaben. Gefördert von: Beijing Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For diabetics, taking regular blood glucose measurements is crucial. However, traditional blood glucose monitoring methods are invasive and unfriendly to diabetics. Recent studies have proposed a biofluid-based glucose sensing technique that creatively combines wearable devices with noninvasive glucose monitoring technology to enhance diabetes management. This is a revolutionary advance in the diagnosis and management of diabetes, reflects the thoughtful modernization of medicine, and promotes the development of digital medicine. This paper reviews the research progress of noninvasive continuous blood glucose monitoring (CGM), with a focus on the biological liquids that replace blood in monitoring systems, the technical principles of continuous noninvasive glucose detection, and the output and calibration of sensor signals. In addition, the existing limits of noninvasive CGM systems and prospects for the future are discussed. This work serves as a resource for further promoting the development of noninvasive CGM systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes MellitusWearable Electronic DevicesHumansBlood GlucoseBlood Glucose Self-MonitoringMonitoring, Physiologic

Stichwörter der Autor:innen

Glucose monitoringbiosensorblood glucose substitutecontinuous glucose monitordetection methoddiabetesglucose sensingnoninvasive

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, Beijing, 100069, PR China.
  • Beijing Key Laboratory of Environmental Toxicology, Capital Medical University, Beijing, 100069, PR China.

ORCID-Profile: Yueyue Chen

Förderung

  • Beijing Natural Science Foundation

Zitieren

APA

Li, Y., & Chen, Y. (2023). Review of Noninvasive Continuous Glucose Monitoring in Diabetics. ACS Sensors, 8(10), 3659-3679. https://doi.org/10.1021/acssensors.3c01538

Vancouver

Li Y, Chen Y. Review of Noninvasive Continuous Glucose Monitoring in Diabetics. ACS Sensors. 2023;8(10):3659-3679. doi:10.1021/acssensors.3c01538

BibTeX
@article{Li2023,
  author = {Li, Yilin and Chen, Yueyue},
  title = {Review of Noninvasive Continuous Glucose Monitoring in Diabetics},
  journal = {ACS Sensors},
  year = {2023},
  volume = {8},
  number = {10},
  pages = {3659--3679},
  doi = {10.1021/acssensors.3c01538}
}
Kostenlos starten →