Paper-Based All-in-One Origami Nanobiosensor for Point-of-Care Detection of Cardiac Protein Markers in Whole Blood
ACS Sensors · 22.09.2023 · 8 (9) · 3574-3584
DOI: 10.1021/acssensors.3c01221 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 14.09.2023. Verfasst von Hao Fu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada. Hauptthemen laut MEDLINE: Point-of-Care Systems, Point-of-Care Testing. Die Arbeit wurde bisher 44-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: University of Toronto, Canada Foundation for Innovation, McGill University.
Abstract (Originalsprache)
Rapid and accurate diagnosis of cardiovascular diseases (CVDs) at the earliest stage is of paramount importance to improve the treatment outcomes and avoid irreversible damage to a patient's cardiovascular system. Microfluidic paper-based devices (μPADs) represent a promising platform for rapid CVD diagnosis at the point of care (POC). This paper presents an electrochemical μPAD (E-μPAD) with an all-in-one origami design for rapid and POC testing of cardiac protein markers in whole blood. Based on the label-free, electrochemical impedance spectroscopy (EIS) immunoassay, the E-μPAD integrates all essential components on a single chip, including three electrochemical cells, a plasma separation membrane, and a buffer absorption pad, enabling easy and streamlined operations for multiplexed detection of three cardiac protein markers [cardiac troponin I (cTnI), brain natriuretic peptide (BNP)-32, and D-Dimer] on a finger-prick whole blood sample within 46 min. Superior analytical performance is achieved through sensitive EIS measurement on carbon electrodes decorated with semiconductor zinc oxide nanowires (ZnO NWs). Using spiked human plasma samples, ultralow limits of detection (LODs) of E-μPAD are achieved at 4.6 pg/mL (190 fM) for cTnI, 1.2 pg/mL (40 fM) for BNP-32, and 146 pg/mL (730 fM) for D-Dimer. Real human blood samples spiked with purified proteins are also tested, and the device's analytical performance was proven to be comparable to commercial ELISA kits. The all-in-one E-μPAD will allow rapid and sensitive testing of cardiac protein markers through easy operations, which holds great potential for on-site screening of acute CVDs in nonlaboratory settings such as emergency rooms, doctor's offices, or patient homes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada.
- Department of Mechanical Engineering, McGill University, Montreal, QC H3A 0C3, Canada.
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, Guangdong 518058, China.
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China.
- School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215123, China.
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada.
Förderung
- University of Toronto
- Canada Foundation for Innovation
- McGill University
- Xi’an Jiaotong-Liverpool University
- Major Basic Research Project of the Natural Science Foundation of the Jiangsu Higher Education Institutions
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Fu, H., Qin, Z., Li, X., Pan, Y., Xu, H., Pan, P., Song, P., & Liu, X. (2023). Paper-Based All-in-One Origami Nanobiosensor for Point-of-Care Detection of Cardiac Protein Markers in Whole Blood. ACS Sensors, 8(9), 3574-3584. https://doi.org/10.1021/acssensors.3c01221
Vancouver
Fu H, Qin Z, Li X, Pan Y, Xu H, Pan P, et al. Paper-Based All-in-One Origami Nanobiosensor for Point-of-Care Detection of Cardiac Protein Markers in Whole Blood. ACS Sensors. 2023;8(9):3574-3584. doi:10.1021/acssensors.3c01221
BibTeX
@article{Fu2023,
author = {Fu, Hao and Qin, Zhen and Li, Xiao and Pan, Yueyue and Xu, Haitong and Pan, Peng and Song, Pengfei and Liu, Xinyu},
title = {Paper-Based All-in-One Origami Nanobiosensor for Point-of-Care Detection of Cardiac Protein Markers in Whole Blood},
journal = {ACS Sensors},
year = {2023},
volume = {8},
number = {9},
pages = {3574--3584},
doi = {10.1021/acssensors.3c01221}
}
EUVIMED