EUVIMEDEUVIMED entdecken
Validierungsstudie

Derivation and Validation of Thresholds Using Synthetic Data Methods for Single-Test Screening of Emergency Department Patients with Possible Acute Myocardial Infarction Using a Point-of-Care Troponin Assay

John W Pickering iD, Joanna M Young, Peter M George, Antony S Watson, Sally J Aldous, Toby Verryt, Richard W Troughton, Christopher J Pemberton, A Mark Richards iD, Louise A Cullen iD, Fred S Apple, Martin P Than

The Journal of Applied Laboratory Medicine · 02.05.2024 · 9 (3) · 526-539

DOI: 10.1093/jalm/jfae001 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift The Journal of Applied Laboratory Medicine, online erschienen am 05.03.2024. Verfasst von John W Pickering und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Christchurch Hospital, Christchurch, New Zealand. Hauptthemen laut MEDLINE: Myocardial Infarction, Emergency Service, Hospital, Troponin I. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Single-sample (screening) rule-out of acute myocardial infarction (AMI) with troponin requires derivation of a single-test screening threshold. In data sets with small event numbers, the lowest one or two concentrations of myocardial infarction (MI) patients dictate the threshold. This is not optimal. We aimed to demonstrate a process incorporating both real and synthetic data for deriving such thresholds using a novel pre-production high-precision point-of-care assay. Methods cTnI concentrations were measured from thawed plasma using the Troponin I Next (TnI-Nx) assay (i-STAT; Abbott) in adults on arrival to the emergency department with symptoms suggestive of AMI. The primary outcome was an AMI or cardiac death within 30 days. We used internal–external validation with synthetic data production based on clinical and demographic data, plus the measured TnI-Nx concentration, to derive and validate decision thresholds for TnI-Nx. The target low-risk threshold was a sensitivity of 99% and a high-risk threshold specificity of >95%.

Results

In total, 1356 patients were included, of whom 191 (14.1%) had the primary outcome. A total of 500 synthetic data sets were constructed. The mean low-risk threshold was determined to be 5 ng/L. This categorized 38% (95% CI, 6%–68%) to low-risk with a sensitivity of 99.0% (95% CI, 98.6%–99.5%) and a negative predictive value of 99.4% (95% CI, 97.6%–99.8%). A similarly derived high-risk threshold of 25 ng/L had a specificity of 95.0% (95% CI, 94.8%–95.1%) and a positive predictive value of 74.8% (95% CI, 71.5%–78.0%).

Conclusions

With the TnI-Nx assay, we successfully demonstrated an approach using synthetic data generation to derive low-risk thresholds for safe and effective screening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial InfarctionEmergency Service, HospitalTroponin IHumansMaleFemaleMiddle AgedAgedPoint-of-Care TestingBiomarkersPoint-of-Care SystemsSensitivity and SpecificityMass Screening

Substanzen

Troponin IBiomarkers

Autor:innen und Institutionen

  • Department of Emergency Medicine, Christchurch Hospital, Christchurch, New Zealand.
  • Christchurch Heart Institute, University of Otago Christchurch, Christchurch, New Zealand.
  • Mater Pathology, Brisbane, Australia.
  • Cardiology Department, Christchurch Hospital, Christchurch, New Zealand.
  • Cardiovascular Research Institute, National University of Singapore, Singapore.
  • Emergency Department, Royal Brisbane and Women's Hospital, Brisbane, Australia.

ORCID-Profile: John W Pickering, A Mark Richards, Louise A Cullen

Zitieren

APA

Pickering, J. W., Young, J. M., George, P. M., Watson, A. S., Aldous, S. J., Verryt, T., Troughton, R. W., Pemberton, C. J., Richards, A. M., Cullen, L. A., Apple, F. S., & Than, M. P. (2024). Derivation and Validation of Thresholds Using Synthetic Data Methods for Single-Test Screening of Emergency Department Patients with Possible Acute Myocardial Infarction Using a Point-of-Care Troponin Assay. The Journal of Applied Laboratory Medicine, 9(3), 526-539. https://doi.org/10.1093/jalm/jfae001

Vancouver

Pickering JW, Young JM, George PM, Watson AS, Aldous SJ, Verryt T, et al. Derivation and Validation of Thresholds Using Synthetic Data Methods for Single-Test Screening of Emergency Department Patients with Possible Acute Myocardial Infarction Using a Point-of-Care Troponin Assay. The Journal of Applied Laboratory Medicine. 2024;9(3):526-539. doi:10.1093/jalm/jfae001

BibTeX
@article{Pickering2024,
  author = {Pickering, John W and Young, Joanna M and George, Peter M and Watson, Antony S and Aldous, Sally J and Verryt, Toby and Troughton, Richard W and Pemberton, Christopher J and Richards, A Mark and Cullen, Louise A and Apple, Fred S and Than, Martin P},
  title = {Derivation and Validation of Thresholds Using Synthetic Data Methods for Single-Test Screening of Emergency Department Patients with Possible Acute Myocardial Infarction Using a Point-of-Care Troponin Assay},
  journal = {The Journal of Applied Laboratory Medicine},
  year = {2024},
  volume = {9},
  number = {3},
  pages = {526--539},
  doi = {10.1093/jalm/jfae001}
}
Kostenlos starten →