WS 2 and WS 2 -ZnO Chemiresistive Gas Sensors: The Role of Analyte Charge Asymmetry and Molecular Size
ACS Sensors · 28.04.2023 · 8 (4) · 1630-1638
DOI: 10.1021/acssensors.2c02762 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 16.03.2023. Verfasst von Farman Ullah und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada. Hauptthemen laut MEDLINE: Acetone, Zinc Oxide. Die Arbeit wurde bisher 54-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Canada Foundation for Innovation, Ontario Research Foundation, Waterloo Institute for Nanotechnology, University of Waterloo.
Abstract (Originalsprache)
We investigate the interaction of various analytes (toluene, acetone, ethanol, and water) possessing different structures, bonding, and molecular sizes with a laser-exfoliated WS2 sensing material in a chemiresistive sensor. The sensor showed a clear response to all analytes, which was significantly enhanced by modifying the WS2 surface. This was achieved by creating WS2-ZnO heterojunctions via the deposition of ZnO nanoparticles on the WS2 surface with a high-throughput, atmospheric-pressure spatial atomic layer deposition system. Water and ethanol produced a much higher response compared to acetone and toluene for both the WS2 and WS2-ZnO sensing mediums. We resolved that the charge-asymmetry points in analyte molecules play a key role in determining the sensor response. High charge-asymmetry points correspond to highly polar bonds (HPBs) in a neutral molecule that have a high probability of interaction with the sensing medium. Our results indicate that the polarity of the HPBs primarily dictates the interaction between the analyte and sensing medium and consequently controls the response of the sensor. Moreover, the size of the analyte molecule was found to affect the sensing response; if two molecules have the same HPBs and are exposed to the same sensing medium, the smaller molecule is likely to produce a higher and faster response. Our study provides a comprehensive picture of analyte-sensor interactions that can help in advancing semiconductor gas sensors, including those based on two-dimensional materials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
- Department of Materials Science and Engineering, Southern University of Science and Technology 1088 Xueyuan Avenue, Shenzhen 517055, China.
- Department of Physics and Astronomy, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
ORCID-Profile: Kissan Mistry, Abdus Samad, Ahmed Shahin, Kevin Musselman
Förderung
- Canada Foundation for Innovation
- Ontario Research Foundation
- Waterloo Institute for Nanotechnology, University of Waterloo
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Ullah, F., Ibrahim, K., Mistry, K., Samad, A., Shahin, A., Sanderson, J., & Musselman, K. (2023). WS 2 and WS 2 -ZnO Chemiresistive Gas Sensors: The Role of Analyte Charge Asymmetry and Molecular Size. ACS Sensors, 8(4), 1630-1638. https://doi.org/10.1021/acssensors.2c02762
Vancouver
Ullah F, Ibrahim K, Mistry K, Samad A, Shahin A, Sanderson J, et al. WS 2 and WS 2 -ZnO Chemiresistive Gas Sensors: The Role of Analyte Charge Asymmetry and Molecular Size. ACS Sensors. 2023;8(4):1630-1638. doi:10.1021/acssensors.2c02762
BibTeX
@article{Ullah2023,
author = {Ullah, Farman and Ibrahim, Khaled and Mistry, Kissan and Samad, Abdus and Shahin, Ahmed and Sanderson, Joseph and Musselman, Kevin},
title = {WS 2 and WS 2 -ZnO Chemiresistive Gas Sensors: The Role of Analyte Charge Asymmetry and Molecular Size},
journal = {ACS Sensors},
year = {2023},
volume = {8},
number = {4},
pages = {1630--1638},
doi = {10.1021/acssensors.2c02762}
}
EUVIMED