EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Plasma-Activated 3D-Printed Electrode for the Determination of Tolfenamic Acid in Environmental Samples

Cassiano Cunha de Souza iD, Francisco Walison Lima Silva, Anne Alves Macedo iD, Dayenny Louise D̀Amato iD, Célia Machado Ronconi iD, Wallace Burger Veríssimo de Oliveira iD, Raquel G Rocha, Lucas V de Faria, Fernando Henrique Cincotto, Rodrigo Alejandro Abarza Muñoz iD, Maria Auxiliadora Costa Matos, Renato Camargo Matos iD

ACS Omega · 10.11.2026 · 11 (44) · 69013-69025

DOI: 10.1021/acsomega.6c08647 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 29.10.2026. Verfasst von Cassiano Cunha de Souza und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais 36036-900, Brazil. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Funda??o de Amparo ? Pesquisa do Estado de Minas Gerais, Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico, Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The occurrence of tolfenamic acid (TA) in aquatic environments has raised concerns regarding its potential environmental impacts, highlighting the need for rapid, sensitive, and low-cost analytical methods for its determination. In this work, a conductive CB/PLA filament was fabricated through a solvent-free thermal mixing approach and used to produce a 3D-printed electrochemical sensor for TA determination. This strategy provides a greener and scalable route for electrode fabrication. Atmospheric air plasma treatment was applied to improve the electrochemical performance of the CB/PLA electrode. SEM images revealed the partial removal of the insulating PLA matrix, increasing the exposure of the conductive carbon sites. This modification resulted in lower charge-transfer resistance (Rct from 33.4 to 7.6 kΩ). Under optimized differential pulse voltammetry conditions, the plasma-treated electrode (CB/PLA-PT) exhibited a linear response toward TA in the concentration range of 1.91–20.1 μmol L–1, with detection and quantification limits of 0.54 and 1.80 μmol L–1, respectively. The sensor demonstrated satisfactory precision (RSD ≤ 5.7%) and selectivity in the presence of common interfering species. Its applicability was successfully demonstrated in spiked river and tap water samples, yielding recovery values between 92 and 105%. The proposed approach combines 3D printing and reagent-free plasma activation to provide a simple and environmentally friendly platform for the electrochemical determination of TA in environmental waters.

Autor:innen und Institutionen

  • Department of Chemistry, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais 36036-900, Brazil.
  • Institute of Chemistry, Federal University of Rio de Janeiro, Rio de Janeiro, Rio de Janeiro 21941-909, Brazil.
  • Institute of Chemistry, Fluminense Federal University, Niterói, Rio de Janeiro 24020-141, Brazil.
  • Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo, São Paulo 05508-000, Brazil.
  • National Institute of Science and Technology of Bioanalytics - Lauro Kubota (INCTBio-LK), Institute of Chemistry, University of Campinas, Campinas, São Paulo 13083-970, Brazil.
  • Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais 38408-100, Brazil.

ORCID-Profile: Cassiano Cunha de Souza, Anne Alves Macedo, Dayenny Louise D̀Amato, Célia Machado Ronconi, Wallace Burger Veríssimo de Oliveira, Rodrigo Alejandro Abarza Muñoz, Renato Camargo Matos

Förderung

  • Funda??o de Amparo ? Pesquisa do Estado de Minas Gerais
  • Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico
  • Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior

Zitieren

APA

de Souza, C. C., Silva, F. W. L., Alves Macedo, A., D̀Amato, D. L., Ronconi, C. M., de Oliveira, W. B. V., Rocha, R. G., de Faria, L. V., Cincotto, F. H., Muñoz, R. A. A., Matos, M. A. C., & Matos, R. C. (2026). Plasma-Activated 3D-Printed Electrode for the Determination of Tolfenamic Acid in Environmental Samples. ACS Omega, 11(44), 69013-69025. https://doi.org/10.1021/acsomega.6c08647

Vancouver

de Souza CC, Silva FWL, Alves Macedo A, D̀Amato DL, Ronconi CM, de Oliveira WBV, et al. Plasma-Activated 3D-Printed Electrode for the Determination of Tolfenamic Acid in Environmental Samples. ACS Omega. 2026;11(44):69013-69025. doi:10.1021/acsomega.6c08647

BibTeX
@article{deSouza2026,
  author = {de Souza, Cassiano Cunha and Silva, Francisco Walison Lima and Alves Macedo, Anne and D̀Amato, Dayenny Louise and Ronconi, Célia Machado and de Oliveira, Wallace Burger Veríssimo and Rocha, Raquel G and de Faria, Lucas V and Cincotto, Fernando Henrique and Muñoz, Rodrigo Alejandro Abarza and Matos, Maria Auxiliadora Costa and Matos, Renato Camargo},
  title = {Plasma-Activated 3D-Printed Electrode for the Determination of Tolfenamic Acid in Environmental Samples},
  journal = {ACS Omega},
  year = {2026},
  volume = {11},
  number = {44},
  pages = {69013--69025},
  doi = {10.1021/acsomega.6c08647}
}